background image

BIO Pellet Stoves

 

27

 

 

 

 

 

GUARANTEE 

Fair srl guarantees the quality of manufacture and of the materials used.  

The Guarantee is valid for a period of 2 years, and runs from the date of first start-up performed within 20 days of 

the purchase by personnel certified by Fair authorised §Service Centre, as long as 24 months have not elapsed 

since the purchase date. In this case, the Guarantee will have to be recognised by the seller.  

The first start-up is flat-rate at the user's expense.  

The certificate must be marked by the stamp of the staff that carried out the installation.  

During that period, the dealer undertakes to repair and/or replace free of charge those parts which in its own 

exclusive judgement prove to be defective.  

Such repairs shall not alter the date of expiry of the Guarantee.  

 

The Guarantee is valid only on the following conditions:  

1 - The appliance must be installed with standard fume piping for pellet stoves with maximum length of 3/5 

metres including elbows (for different application, contact customer service).  

2 - Do not install on your own.  

3 -  Extraordinary maintenance must be carried out once a year by Fair Authorised Service Centres. 

4 – All the procedures in the "Maintenance" chapter must be observed carefully.  

 

The Guarantee does not cover:  

1 - Damage caused by incorrect installation of the equipment or by unsuitability of the system.  

2 - Faults resulting from negligence, lack of care, incompetent use, or repairs carried out by non-authorised third 

parties.  

3 - Damage caused by transportation.  

4 - Work to modify parameters or chimney flue.  

5 - Parts normally subject to wear or which last less than the aforementioned Guarantee period. For example:  

the glow plug, gaskets, the brazier, the firebox lining, ceramic glass, painted parts of ceramic etc.  

 

The guarantee is valid for 24 months from the date of first startup as indicated on this certificate, which should be 

completed correctly and accompanied by the receipt of purchase as proof. The apparatus is not guaranteed in 

any way for non-domestic use.   

 

The same applies in the event that the staff of the Technical Service Centre or of Fair srl discover while doing 

repairs that the date of installation/first startup is not the true one (which can be detected from identifying details 

and other elements in the equipment).  

The present certificate must be presented to the staff of the Authorised Customer Service Centre, together with a 

document of proof of purchase (invoice or docket), every time the client ask for an intervention during the 

guarantee period.  

Fair srl will not be liable for loss or damage caused to persons or things resulting from breakdown, forced 

suspension of use of the equipment or improper use.  

 

The Guarantee is valid only on the following conditions:  

1 - The equipment must be installed by qualified personnel.  

2 - The instalment must be done in accordance with the Laws in force in the territory and according to the 

directions given in the instruction manual.  

3 - Any repairs must be carried out only by staff of Authorised Service Centres.  

4 -  The Guarantee certificate must be completed in all its parts in a clear and readable manner. 

5 - If routine maintenance is performed regularly.  

6 - If the appliance is earthed.  

 

Fair srl grants no other Guarantees apart from the above.  

In case of any dispute, the Court of Vicenza shall have Jurisdiction. 

IMPORTANT: the first start-up is t the client's expenses.  

 

European Guarantee: 24 months on spare parts and labour.  

 

Registering your new stove 
Henley Stoves does not accept warranty submissions through post/email 
Please register your warranty at 

https://henleystoves.com/henley-warranty/

 

 

The appliance must be installed by a HETAS / METAC approved fitter in accordance with Building 

Regulations in order for the warranty to be valid. 

 

If upon opening the stove, it is found to be damaged in any way, do not attempt to install the stove. 

Return to retailer where it was purchased from. 

Summary of Contents for BIO80

Page 1: ...Maintenance and UserManual Pellet Stove BIO 80 BIO 80Q IMPORTANT This Appliance must be fitted by a HETAS METAC Qualified Installer...

Page 2: ...evel Automatic temperature control The internal thermostat senses the temperature environment and maintains it constant according to the settings inserted Control display The control display allows ad...

Page 3: ...of the installed product Fair will not be liable in the event of failure to respect these instructions This stove should be used for the purposes for which it was designed and made The manufacturer is...

Page 4: ...online stove output to room size calculator to help you decide the correct size space for your new stove My Pellet Stove doesn t turn OFF straight away This is because of the built in Cleaning feature...

Page 5: ...e the stove will extract the smoke given time turning off the stove while there is smoke will cause further smoke to build and not be extracted How to register my new stoves warranty Henley Stoves doe...

Page 6: ...block chimneys connecting flue pipe system must meet requirements of the Building Regulations We recommend a flexible flue liner system certified for use with solid fuel systems be used to improve sto...

Page 7: ...raught which is necessary for the different models of pellets stoves is 8pa to 12pa 0 08 to 0 12mbar Point where the flue passes through weather surface Note 1 2 Clearances to the flue outlet A At or...

Page 8: ...t 1m above the highest point of contact of chimney and roof Where the roof has a pitch of more than 10 on both sides and the outlet is at the ridge or within 600mm of it the height of the chimney or f...

Page 9: ...ermetically sealed doors and windows The situation can also be problematical when on the other hand there are drafts inside the room generated by fans in the kitchen or bathroom for example To avoid t...

Page 10: ...minimum thickness 0 5mm with a diameter of 80 mm or 100mm depending on the type of plant see picture 2 pag 6 you can not use pipes made of asbestos cement or flexible metal The pipes must be sealed wi...

Page 11: ...nly combustible material you can use You can find different kind of pellets with different characteristics and quality on sale We recommend to use pellets of good quality as that has great influence o...

Page 12: ...ion methods there must be a minimum distance of at least 20 cm from flammable objects sofas furniture wooden covering to the back and side of the stove and of 80 cm to the front where the fire door is...

Page 13: ...r for 2 3 days display A will show the number 3 so that the mechanical parts are able to settle into smooth running IMPORTANT Continuous operation of the stove at maximum power may shorten the expecte...

Page 14: ...t shows the state of the stove During functioning it shows the temperature chosen by the user During input setting it shows the parameter you are changing Starting To start the stove keep key P4 press...

Page 15: ...y B Fumes gas temperature To verify the fumes gas temperature at the outlet keep key P1 pressed for few seconds Switching off To switch off the stove keep P4 pressed Clean final will be displayed Duri...

Page 16: ...ON for example h 17 00 and turn OFF for example h 21 00 Press set P3 to confirm each time The situation could be the following Daily Program Start 1 Stop 1 Start 2 Stop 2 ON h 6 30 h 10 30 h 17 00 h...

Page 17: ...ms in order to avoid any crossover with weekend program M2 4 Go into setting M2 4 press set P3 decide ON OFF then confirm with set P3 If you decide ON the green light will switch ON This green light w...

Page 18: ...C delta T Menu 05 Menu 06 Menu 07 ATTENTION These menus functions are exclusively for the Technical service improper use can affect the functioning of the stove itself Menu 08 This Menu shall not be...

Page 19: ...lay A will show the message Off The remote control operates with a 12 Volt MN21 type battery The batteries should be removed from the device before it is disposed of and must themselves be disposed of...

Page 20: ...al 3 Hot Exhaust will appear on display the pellets stoking is decreased and the card makes the fumes extractor work at its minimum speed to take the temperature back to the setlimits If temperature...

Page 21: ...assistance for the maintenance to a qualified professional Do not do it can cause damage to the heater and its electrical and mechanical parts thereby affecting the operation safety and validity of th...

Page 22: ...lour if it is red that means it is weak if there is black smoke that means the brazier is dirty and it must be cleaned Ash draw cleaning Pic 14a IMPORTANT When refitting brazier ensure the above side...

Page 23: ...Average temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical inpu...

Page 24: ...verage temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical input...

Page 25: ...BIO Pellet Stoves 24 Wiring diagram N100 For the correct operation of the stove respect the polarity of the thermo couple...

Page 26: ...tions of the air inlet on the back of the stove brazier grid holes obstructed and or brazier box with too much hash exchanger pipes too dirty clean the extractor blades and its scroll see Maintenance...

Page 27: ...ll the tank Clean the brazier see Maintenance Empty the brazier and start again if the problem continues call a specialised technician Replace the plug Call a specialised technician Restart the stove...

Page 28: ...ot Have it cleaned immediately Pellets can burn thanks to the chimney flue depression without the aspirator Have it replaced immediately as it can be bad for your health Call a specialised technician...

Page 29: ...rtificate which should be completed correctly and accompanied by the receipt of purchase as proof The apparatus is not guaranteed in any way for non domestic use The same applies in the event that the...

Page 30: ...ise you to always refer to the dealer who sold the apparatus to you or to our nearest Technical Servicing Centre specifying the model and serial number and describing the problem Also bear in mind tha...

Page 31: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Page 32: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Page 33: ...BIO Pellet Stoves 31...

Page 34: ...BIO Pellet Stoves FAIR srl Via Lago di Costanza 24 Z I 36015 Schio Vicenza Italia Tel 39 0445 698000 Fax 39 0445 698100 www fair europe com info fair europe com Copyright Fair Rev 6 14 02 2019 EN...

Reviews: