![FAIR BIO80 Maintenance And User Manual Download Page 21](http://html1.mh-extra.com/html/fair/bio80/bio80_maintenance-and-user-manual_3207389021.webp)
BIO Pellet Stoves
20
Alarm 7 - Tank safety
There is a manual winding thermostat near the tank, which controls if the temperature exceeds
the allowed limits preventing in this way the pellets from catching fire because of the over-heating. “Al
7 alar al 7 Safety Thermal” will appear on display and the thermostat stops the electrical input to the
cochlea blocking the pellets stoking of the brazier and starting the switching off phase. Let the stove
cool down and then switch it off with (P4) ON/OFF button. Verify the occurring problem on page 24.
After solving the problem clean up the brazier and start the stove with (P4) ON/OFF button.
Alarm 8 - Pressure switch
A pressure switch is connected to the boiler pipeline to check the depression. If “Al 8 alar al 8 Failure
Depress” appears on display the pressure switch stops the electric input to the cochlea blocking
the pellets stoking to the brazier and starting the switching off phase. The electronic card makes the
fumes extractor work at maximum speed and then turns it off within 20 minutes. Switch the stove off
with (P4) ON/OFF button. Verify the occurring fault on page 24. After solving the problem clean up the
brazier and start the stove with (P4) ON/OFF button.
SerV - Maintenance
When "SerV" appears in the display, it means that have been reached preset maximum working
hours. Request assistance for the maintenance to a qualified professional. Do not do it can cause
damage to the heater and its electrical and mechanical parts, thereby affecting the operation, safety
and validity of the guarantee.
•
MAINTENANCE
Introduction
To extend the life of your stove it is important to clean it periodically as indicated hereafter. It is also
necessary to have an extraordinary maintenance intervention done on the stove and chimney once a
year calling the assistance service on time. Do not use steel-wool, muriatic acid or corrosive and
scratching products to clean its inner and exterior parts. In case of damages always use original spare
parts asking to authorised shops or to the manufacturer.
IMPORTANT! before cleaning or performing maintenance let the fire go out completely and the stove
cool down and disconnect it from electrical power supply.
Painted metal parts cleaning
Use a wet soft cloth to clean the painted metal parts. Do not use degreasing substances, alcohol,
diluent, acetone, petrol that can damage irreparably the paint.
Glass cleaning
The fire-door pyroceram resists to 700°C but not to sudden changes of temperature. Therefore you can
clean the glass with normal glass products but you have to wait for the glass to cool down to avoid its
explosion. If you break the glass you must replace it before using the stove.
Fumes ducts cleaning
Using brushes clean the soot from: the fume duct, the chimney flue and the chimney pot. A specialised
technician should carry out this cleaning and verify its effectiveness.
Summary of Contents for BIO80
Page 33: ...BIO Pellet Stoves 31...