INSTALLATION 

Introduction  

The stove position must be chosen in accordance with the environment, the waste pipe and the chimney 

flue. Verify with the local authority if there are restrictive rules about the air intake for combustion 

purposes and ventilation of domestic environment and about the waste fumes pipes plant with chimney 

flue and chimney pot. The manufacturer declines any responsibility in case of installation not in 

accordance with the standards in force, with a not correct ventilation system, an electrical connection 

not in accordance with the standards in force, or in case of bad use of the appliance.  

The installation must be carried out by a qualified technician who will sign a declaration of conformity of 

the system and take all responsibility for the installation and good functioning of the appliance. A booklet 

of testing and periodic maintenance to be carried out by the installer is issued to the client together with 

the stove.

  

 

Installation  

The appliance should be installed on a floor with 

adequate load bearing capacity. If the existing structure 

does not satisfy this requirement it is essential to take 

appropriate precautions (e.g. install a load distribution 

plate).  Insert and adjust the 4 feet that are supplied or 

adjust them if already installed, so that the base of the 

stove becomes detached from the floor. When the 

appliance is installed it should be placed so as to allow 

easy access for cleaning the stove itself, the exhaust gas 

ducts and the chimney flue.  

The pellets stove must be installed in isolation, with a 

minimum air space of 15 cm to allow an adequate cooling 

of the appliance and a good distribution of heat in the 

domestic environment. In compliance with fire-prevention 

methods there must be a minimum distance of at least 20 

cm from flammable objects (sofas, furniture, wooden 

covering) to the back and side of the stove and of 80 cm  

to the front where the fire door is. If the floor is made of 

flammable material you must prepare a coverage made  

Pic.10 

of non-flammable material (plate of steel, marble, refractory material), which sticks out 50 cm from the 

front of the stove where the fire door is and 20 cm from the other sides (see picture 10). You can’t install 

the stove in bedrooms or bathrooms. 

  

 

Electrical connection  

IMPORTANT! the appliance must be installed by specialised staff. The electrical connection must be 

carried out using the supplied cable, adding an adequate plug on a socket which can take the load factor 

and voltage specific of each model as indicated on the technical data table (see pages 20, 21), the plug 

must be accessible when the appliance is installed. It is necessary that the fixed power grid is protected 

with a single pole switch to assure a complete disconnection with a minimum opening between the 

contacts of 3 mm. Make sure there is an efficient grounding, if there isn’t one or it is inefficient you 

should provide to have a grounding installed in compliance with the standards in force.  

 

N.B. The stove heating system is protected by fuse located inside the main switch behind the stove. 

Always remember to disconnect the power supply before carrying out any maintenance and/or checks!  

 

Use of an external thermostat  

The stove is already operating via an ambient probe positioned behind it. It is recommended to check 

its position and not to pass it near any heat source. If you want to connect an outside room thermostat 

of any type to a stove, use a 2x0.5mm2 cable, make it through the hole beneath the tank and connect 

it to the electronic board in the 2-pin "External Thermostat" housing. (see electric diagram p.22). These 

operations must be carried out by a specialized technician.  

Summary of Contents for BIO80

Page 1: ...Maintenance and UserManual Pellet Stove BIO 80 BIO 80Q IMPORTANT This Appliance must be fitted by a HETAS METAC Qualified Installer...

Page 2: ...evel Automatic temperature control The internal thermostat senses the temperature environment and maintains it constant according to the settings inserted Control display The control display allows ad...

Page 3: ...of the installed product Fair will not be liable in the event of failure to respect these instructions This stove should be used for the purposes for which it was designed and made The manufacturer is...

Page 4: ...online stove output to room size calculator to help you decide the correct size space for your new stove My Pellet Stove doesn t turn OFF straight away This is because of the built in Cleaning feature...

Page 5: ...e the stove will extract the smoke given time turning off the stove while there is smoke will cause further smoke to build and not be extracted How to register my new stoves warranty Henley Stoves doe...

Page 6: ...block chimneys connecting flue pipe system must meet requirements of the Building Regulations We recommend a flexible flue liner system certified for use with solid fuel systems be used to improve sto...

Page 7: ...raught which is necessary for the different models of pellets stoves is 8pa to 12pa 0 08 to 0 12mbar Point where the flue passes through weather surface Note 1 2 Clearances to the flue outlet A At or...

Page 8: ...t 1m above the highest point of contact of chimney and roof Where the roof has a pitch of more than 10 on both sides and the outlet is at the ridge or within 600mm of it the height of the chimney or f...

Page 9: ...ermetically sealed doors and windows The situation can also be problematical when on the other hand there are drafts inside the room generated by fans in the kitchen or bathroom for example To avoid t...

Page 10: ...minimum thickness 0 5mm with a diameter of 80 mm or 100mm depending on the type of plant see picture 2 pag 6 you can not use pipes made of asbestos cement or flexible metal The pipes must be sealed wi...

Page 11: ...nly combustible material you can use You can find different kind of pellets with different characteristics and quality on sale We recommend to use pellets of good quality as that has great influence o...

Page 12: ...ion methods there must be a minimum distance of at least 20 cm from flammable objects sofas furniture wooden covering to the back and side of the stove and of 80 cm to the front where the fire door is...

Page 13: ...r for 2 3 days display A will show the number 3 so that the mechanical parts are able to settle into smooth running IMPORTANT Continuous operation of the stove at maximum power may shorten the expecte...

Page 14: ...t shows the state of the stove During functioning it shows the temperature chosen by the user During input setting it shows the parameter you are changing Starting To start the stove keep key P4 press...

Page 15: ...y B Fumes gas temperature To verify the fumes gas temperature at the outlet keep key P1 pressed for few seconds Switching off To switch off the stove keep P4 pressed Clean final will be displayed Duri...

Page 16: ...ON for example h 17 00 and turn OFF for example h 21 00 Press set P3 to confirm each time The situation could be the following Daily Program Start 1 Stop 1 Start 2 Stop 2 ON h 6 30 h 10 30 h 17 00 h...

Page 17: ...ms in order to avoid any crossover with weekend program M2 4 Go into setting M2 4 press set P3 decide ON OFF then confirm with set P3 If you decide ON the green light will switch ON This green light w...

Page 18: ...C delta T Menu 05 Menu 06 Menu 07 ATTENTION These menus functions are exclusively for the Technical service improper use can affect the functioning of the stove itself Menu 08 This Menu shall not be...

Page 19: ...lay A will show the message Off The remote control operates with a 12 Volt MN21 type battery The batteries should be removed from the device before it is disposed of and must themselves be disposed of...

Page 20: ...al 3 Hot Exhaust will appear on display the pellets stoking is decreased and the card makes the fumes extractor work at its minimum speed to take the temperature back to the setlimits If temperature...

Page 21: ...assistance for the maintenance to a qualified professional Do not do it can cause damage to the heater and its electrical and mechanical parts thereby affecting the operation safety and validity of th...

Page 22: ...lour if it is red that means it is weak if there is black smoke that means the brazier is dirty and it must be cleaned Ash draw cleaning Pic 14a IMPORTANT When refitting brazier ensure the above side...

Page 23: ...Average temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical inpu...

Page 24: ...verage temperature fumes 92 5 167 C Mass flow fumes 2 9 5 5 g s Tank capacity 15 kg Volume to heat 150 240 m3 Air flow max 190 m3 h Autonomy 10 26 h Air fumes tubes diameter 40 80 mm Electrical input...

Page 25: ...BIO Pellet Stoves 24 Wiring diagram N100 For the correct operation of the stove respect the polarity of the thermo couple...

Page 26: ...tions of the air inlet on the back of the stove brazier grid holes obstructed and or brazier box with too much hash exchanger pipes too dirty clean the extractor blades and its scroll see Maintenance...

Page 27: ...ll the tank Clean the brazier see Maintenance Empty the brazier and start again if the problem continues call a specialised technician Replace the plug Call a specialised technician Restart the stove...

Page 28: ...ot Have it cleaned immediately Pellets can burn thanks to the chimney flue depression without the aspirator Have it replaced immediately as it can be bad for your health Call a specialised technician...

Page 29: ...rtificate which should be completed correctly and accompanied by the receipt of purchase as proof The apparatus is not guaranteed in any way for non domestic use The same applies in the event that the...

Page 30: ...ise you to always refer to the dealer who sold the apparatus to you or to our nearest Technical Servicing Centre specifying the model and serial number and describing the problem Also bear in mind tha...

Page 31: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Page 32: ...Centre Work done on Specialised Technical Servicing Centre Material used Guarantee YES NO YES NO YES NO YES NO User s signature Segnature of TSC Material used Guarantee YES NO YES NO YES NO YES NO Us...

Page 33: ...BIO Pellet Stoves 31...

Page 34: ...BIO Pellet Stoves FAIR srl Via Lago di Costanza 24 Z I 36015 Schio Vicenza Italia Tel 39 0445 698000 Fax 39 0445 698100 www fair europe com info fair europe com Copyright Fair Rev 6 14 02 2019 EN...

Reviews: