BIO Pellet Stoves
25
The stove switches off.
Alarm displayed: “Al 2 alar
al 2 Probe Exhaust”
•
Fumes feeler is faulty
•
Electronic card faulty
•
The environment exchanger fan doesn’t
work
•
Too high parameter set on card during
phase 5
•
Replace the feeler. Call a specialised
technician.
•
Replace the card. Call a specialised
technician.
•
Replace the fan. Call a specialised
technician.
•
Call a specialised technician to
regulate the pellets stoke.
The stove is in steady
condition, the display
shows: “Al 3 alar al 3 Hot
Exhaust”
•
Environment temperature reached
•
Fumes outlet temperature reached
•
The stove works at minimum rate: no
problem.
•
The stove works at minimum rate: no
problem.
The stove switches off.
Alarm displayed: "Al 4 alar
al 4 Fan Failure"
•
Internal fan disconnected or faulty
•
Encoder disconnected or faulty
•
Check that the encoder is connected
to the board and that the fan is
working. Call specialized technician.
•
Replace the encoder or fan, call a
specialized technician.
The stove doesn’t start.
Alarm displayed: “Al 5 alar
al 5 No Lightin-”
•
The tank is empty
•
The brazier isn’t cleaned
•
The feeler hasn’t detected the minimum
threshold to start
•
Starting plug is faulty
•
Outside temperature is too cold
•
Pellets are wet
•
Thermal feeler is blocked
•
Electronic card is faulty
•
Fill the tank.
•
Clean the brazier (see Maintenance).
•
Empty the brazier and start again, if
the problem continues call a
specialised technician.
•
Replace the plug. Call a specialised
technician.
•
Restart the stove.
•
Pellets must be stored in a dry room.
Verify.
•
Replace the feeler. Call a specialised
technician.
•
Replace the card. Call a specialised
technician.
Pellets don’t get to the fire
box “Al 6 alar al 6 No
Pellet”
•
The tank is empty
•
Cochlea is blocked by a strange object
(ex. Nails)
•
Cochlea gear motor is damaged
•
Verify if there is an alarm activated on
display (ex. Al 8 Failure Depress…)
•
Fill the tank.
•
Unplug the plug, move the inside
hand protection of the tank, empty the
tank, clean the cochlea e start again.
•
Replace the gear motor. Call a
specialised technician.
•
Call a specialised technician to check
the stove and detect the problem.
The stove switches OFF.
Alarm displayed “Al 7 alar
al 7 Safety Thermal”
•
Stove overheated
•
The exchanger fan doesn’t work
•
Temporary power failure
•
Faulty thermostat
•
Air filter obstructed
•
Faulty electronic card
•
Let the stove cool down and stoke it
again, if the problem continues call a
specialised technician.
•
Replace the fan. Call a specialised
technician.
•
A voltage failure during the
functioning of the stove causes an
overheating of the boiler and it is
necessary to stoke it again and start
the stove.
•
Replace the thermostat. Call a
specialised technician.
•
Clean the filter (see Maintenance).
•
Replace the card. Call a specialised
technician.
Summary of Contents for BIO80