background image

16

Junior 624  - 24V dc

meccanica

FADINI

Elpro  62

GB

4 5

3

1 2 3 4 5 6 7 8 9 10

11 12 13 14

18 19

NC

15 16 17

20

21

22

23

-

+

-

+

Force Trimmer

ST

OP

COMMON

O

P

E

N

CLOSE

NC

Photocell

Coast

radio cont

act

Light 24V - 1W

OUTPUT

 24Vdc forcargo max 500mA:

n°2 p

airs of photocell

n°1 Radio riceiver

n°1 Led selector Chis 37 and Chis e37

+ -

-

+

OUTPUT

 

24Vdc

for flasher

-

+

Output 24V cc/ca for

photocell 

TX set up for DSA

  control

Relay output

Courtesy lamp

max

24V 50mA

Pulse of

programming

LP

NC

Unlock

handle

Switch

L20

L2

L4 L5

L6

L7

L10

Encoder

Battery

12V - 2,2Ah

Battery

12V - 2,2Ah

F1= 6,3A

per 24V

Transformer

External Electrical power

supply 230V 50Hz ±10%

for superior distances

the 50m to increase

the section wires

5A

22V

230V

F2= 6,3A

Battery

+

-

-

+

+

-

Radiocont

act

LED Card

Elpro 62

for JUNIOR 624

24V dc

Fuse terminal

Output for

2°sliding leaf

Elpro 62 SLAVE terminal for

2° sliding operator

Dip- Switch 12= ON

CLOSE

123

4
5
6
7
8
9
10

11

12

P.N.The LED shown here are in their

normal status for correct ELPRO 62

LED on

LED turn off

Junior 624

Led limit

switch

clutch limit

switch

Y

X

Led limit

switch

Dip-Switch

COMMON

max 400Kg

AP

CH

C

NC

Pedestrian

Common

Auxiliary for

2° Junior

Trimmer

Pedestrian

max 3m

ON

OFF

-

+

NOTE: all of the possible connections at the programmer

terminal boards are also illustrated in the respective

instruction sheets for each individual accessory.

L22

L21

Trimmer 

Pause

da 1s - 120s

OPEN

pag 17

Fig. 17

Motor 24V

M

BLACK

WHITE

Motore

-

+

ATTENTION: 

USING  ACCESSORIES THAT

ARE NOT  FADINI MAY RESULT INTO

DAMAGES TO THE BOARD: ALWAYS USE

CLEAN CONTACTS FOR THE NO-NC INPUTS

Summary of Contents for Elpro 62

Page 1: ...LULE SONO ALIMENTATI ATTRAVERSO I MORSETTI DEDICATI 13 14 Fig 17 DEL LIBRETTO ISTRUZIONI PENA IL BLOCCO COSTANTE DEL CANCELLO GB IMPORTANTE IMPORTANT Junior 624 Junior 633 Junior 650 THE CONTROL BOARD...

Page 2: ...45 I Libretto di istruzioni pag 1 16 GB Instructions Manual pag 1 8 17 24 F Notice de montage pag 1 8 25 32 D Betriebsanleitung pag 1 8 33 40 E Manual de instrucciones pag 1 8 41 48 NL Instructieboekj...

Page 3: ...pi ces entretoises et boulons de fixation pas compris dans le kit E Componentes principales para una instalaci n del Junior 624 en la Fig 1 1 Motorreductor deslizante electromec nico serie Junior con...

Page 4: ...de course magn tique P Pignon m4 Z18 Q Couvercle du programmateur R Transformateur 230V 24V 150VA pour Junior 624 E Lista de los componentes principales ilustrados en la Fig 2 A Luz de led azul y mbar...

Page 5: ...03A 6 Lampe clignotante Miri 4 avec antenne 7 Emetteur radio 8 S lecteur cl CHIS 37 Attention v rifier l int grit de la structure et la lin arit du mouvement du portail en liminant d ventuels frotteme...

Page 6: ...pag 5 Fig 5 Fig 6 60mm 60mm Fig 7 Fig 8 60mm 60mm...

Page 7: ...pag 6 Fig 9 96mm 96mm 60mm 96mm 60mm 2mm Fig 10 96mm 60mm 96mm 60mm 2mm 22x8 6 5 M8 96mm...

Page 8: ...pag 7 Fig 11 Fig 12 1 2 3 1 2 3 Fig 13...

Page 9: ...INKS IZQUIERDA LINKS I Finecorsa magnetico GB Magnetic limit switch F Fin de course magn tique D Magnetischer Endschalter E Final de carrera magn tico NL Magnetische eindslag I Finecorsa meccanico GB...

Page 10: ...ction wires 5A 22V 230V F2 6 3A Battery Radiocont act LED Card Elpro 62 for JUNIOR 624 24V dc Fuse terminal Output for 2 sliding leaf Elpro 62 SLAVE terminal for 2 sliding operator Dip Switch 12 ON CL...

Page 11: ...closing slow down reverse run upon contact with an obstacle and LED diagnostics Set up for double sliding exit defined by the way of Dipswitches of the RH nad LH installation Blue Amber LED lamp on th...

Page 12: ...nels All thepossible configurations are attached to their respective command accessories FADINI Output 24V FADINI FADINI Astro 43 FADINI NC NC 1 2 3 4 5 6 NC OPEN CLOSE STOP COMMON RADIO CONTACT COMMO...

Page 13: ...ro 62 MASTER Elpro 62 SLAVE Dip Switch 12 OFF Dip Switch 12 ON terminal 15 open terminal 4 open terminal 16 close terminal 5 close terminal 17 23 common terminal 3 common terminal 22 terminal 16 close...

Page 14: ...OPEN NA External clock Opening by way of external clock Connection connect the NA contact of the clock with terminal 4 OPEN and terminal 3 COMMON in parallel enabling the automatic closing with the D...

Page 15: ...Push and hold down the P botton and then afterwards install the line fuse After 2 3 seconds release the P button the LP LED will begin to flash signalling theprogramming phase 90 LP LP 3 Operation lea...

Page 16: ...onnected to the mains at the PCB IMPORTANT Once the electrical power suply has been disconnected using the unlocking key upon return of the mains electrical power the first movement of the Junior oper...

Page 17: ...mprovement TECHNICAL SPECIFICATIONS AND DIMENSIONS 316 293 140 102 62 5 40 170 38 210 95 40 170 210 296 55 290 160 Technical specifications Electrical power supply 230V 50Hz Motor voltage 24Vdc Max El...

Page 18: ......

Page 19: ......

Page 20: ...ch ohne Vorank ndigung vorzunehmen und bernimmt f r etwaige Fehler bzw Sach und Personensch den keinerlei Haftung El fabricante se reserva el derecho a aportar modificaciones al presente manual sin pr...