![background image](http://html1.mh-extra.com/html/fadini/elpro-62/elpro-62_instruction-manual_537268010.webp)
16
Junior 624 - 24V dc
meccanica
FADINI
Elpro 62
GB
4 5
3
1 2 3 4 5 6 7 8 9 10
11 12 13 14
18 19
NC
15 16 17
20
21
22
23
-
+
-
+
Force Trimmer
ST
OP
COMMON
O
P
E
N
CLOSE
NC
Photocell
Coast
radio cont
act
Light 24V - 1W
OUTPUT
24Vdc forcargo max 500mA:
n°2 p
airs of photocell
n°1 Radio riceiver
n°1 Led selector Chis 37 and Chis e37
+ -
-
+
OUTPUT
24Vdc
for flasher
-
+
Output 24V cc/ca for
photocell
TX set up for DSA
control
Relay output
Courtesy lamp
max
24V 50mA
Pulse of
programming
LP
NC
Unlock
handle
Switch
L20
L2
L4 L5
L6
L7
L10
Encoder
Battery
12V - 2,2Ah
Battery
12V - 2,2Ah
F1= 6,3A
per 24V
Transformer
External Electrical power
supply 230V 50Hz ±10%
for superior distances
the 50m to increase
the section wires
5A
22V
230V
F2= 6,3A
Battery
+
-
-
+
+
-
Radiocont
act
LED Card
Elpro 62
for JUNIOR 624
24V dc
Fuse terminal
Output for
2°sliding leaf
Elpro 62 SLAVE terminal for
2° sliding operator
Dip- Switch 12= ON
CLOSE
123
4
5
6
7
8
9
10
11
12
P.N.The LED shown here are in their
normal status for correct ELPRO 62
LED on
LED turn off
Junior 624
Led limit
switch
clutch limit
switch
Y
X
Led limit
switch
Dip-Switch
COMMON
max 400Kg
AP
CH
C
NC
Pedestrian
Common
Auxiliary for
2° Junior
Trimmer
Pedestrian
max 3m
ON
OFF
-
+
NOTE: all of the possible connections at the programmer
terminal boards are also illustrated in the respective
instruction sheets for each individual accessory.
L22
L21
Trimmer
Pause
da 1s - 120s
OPEN
pag 17
Fig. 17
Motor 24V
M
BLACK
WHITE
Motore
-
+
ATTENTION:
USING ACCESSORIES THAT
ARE NOT FADINI MAY RESULT INTO
DAMAGES TO THE BOARD: ALWAYS USE
CLEAN CONTACTS FOR THE NO-NC INPUTS