POSSIBLE MANFUCTIONS
The LED device on the protective casing enables the installer and the end user to see if the system is actually working
properly ( Blu light ) or if there is some fault that does not permit proper operation (amber light).
ELECTRICAL POWERING BY WAY OF THE BACK-UP
BATTERY
If there is a mains electrical power failure to the system it is possible to power
Elpro 62 by way of commercial type back-up batteries, with two 12 V batteries
at 2.2 Ah, to be lodged in the front of the casing above the cable inputs
autonomy of about 15 complete cycles in one heure). The connection must
be made with 4.2 fastons and connected in series to the input terminals found
behind the PCB.
With mains electrical power connected and functioning, the back-up batteries,if
connected to the terminals on the Elpro 62, are automatically recharged.
NOTE: for proper installation it is necessary that the faston connectors for the
two batteries be on the front side ( in front of the installer) of their insertion.
F1= 6,3A
per 24V
F2= 6,3A
Battery
n°2 - 12V a 2,2Ah
OPENING OF THE UNLOCKING HANDLE LEVER FOR THE MANUAL OPERATION OF THE GATE
Using the unlocking handle lever with the coded key, the electrical power supply
is always disconnected from the system.
For the unlocking and subsequent manual movement of the gate, it is necessary
that the handle be opened until it stops beyond 90°.
Upon closing and subsequent locking of the lock, the electrical power supply
is reconnected to the mains at the PCB.
IMPORTANT: Once the electrical power suply has been disconnected using
the unlocking key, upon return of the mains electrical power, the first
movement of the Junior operator is always toward closing at a normal
operational speed with no programmed slowdowns. To recover all of its
functions (such as slowdown) it is necessary that a full cycle be completed
all the way to the opening limit switch.
FA
D
IN
I
1)
2)
3)
Faults
Causes
P r o c e d u r e
- lack of mains electrical power supply 230V
- 5A line fuse burned
- 6,3A 24 V line fuse burned
- Unlocking handle lock not locked
- Check the line of all fuses
- Close and remuve the key from
the lock
+90°
LED lamp remeins lit
with an amber colour
- Detects the continuous presence of an obstacle or
of possible friction during movements
-Remove obstacel present
-Remove possible causes of friction
on the sliding gate guides
- Operational force too low for the inertia of the gate
- Increase the force on the trimmer
- Contact on the photocell
- Clean and covers of the photocells
- Photocells not aligned
- Batteries dead (Orbita 57)
- Pair of photocells too far
The gate starts to move
then stops or reverses
direction
- Operational force too low for the gate
-detects the continuous presence of an obstacle or of
possible friction during movement
- Increase the force of trimmer
- Remove eventual causes of friction
on the sliding gate guides.
+
-
-
+
+
-
178
35
60
35
The gate doesn't move
- one or more contact NC are open
- burnt fuses
- Check all contacts NC
- Check the state of fuses
Battery
12V - 2,2Ah
Battery
12V - 2,2Ah
+
-
-
+
+
-
A
B
ENCODER Motor
pag 23
Junior 624 - 24V dc
meccanica
FADINI
Elpro 62
GB
Fig. 30
Fig. 31
Fig. 48
Led lamp off