Mini-Mag Service Manual V1.0
7
7-3
BRUSH DRIVE SYSTEM
BRUSH PRESSURE
SWITCH
BAR GRAPH
DISPLAY
TRACTION DRIVE MODELS with CENTRAL COMMAND II
The scrub deck pressure is adjusted continuously while scrubbing. Using the brush
pressure switch on the control panel you set the desired scrubbing pressure. The de-
sired brush pressure is shown on a bar graph on the LCD display. There are 5 different
settings to choose from. The controller is programmed with an amp value for each of 5
brush pressure settings. When the scrub deck starts the controller calculates the amp
draw of the motors and compares it to the amp value of the current brush pressure set-
ting. If the motors are not drawing enough amps the controller lowers the brush deck
to increase the brush pressure on the ground and therefore raise the amp draw of the
motors. If the amp draw of the motors is higher than the target amp value the controller
raises the brush deck to relieve down pressure from the brush deck therefor reducing
the amp draw of the brush motors because they can then turn more easily.
Summary of Contents for MINI-MAG SERIES
Page 2: ......
Page 14: ...Mini Mag Service Manual V1 0 1 1 2 MAINTENANCE ...
Page 15: ...Mini Mag Service Manual V1 0 1 1 3 MAINTENANCE ...
Page 16: ...Mini Mag Service Manual V1 0 1 1 4 MAINTENANCE BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 28: ...Mini Mag Service Manual V1 0 3 3 6 SQUEEGEE SYSTEM SQUEEGEE ADJUSTMENT EXAMPLES ...
Page 30: ...Mini Mag Service Manual V1 0 3 3 8 SQUEEGEE SYSTEM ...
Page 42: ...Magnum Service Manual V1 0 6 6 4 SOLUTION SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...