Mini-Mag Service Manual V1.0
5
5-2
RECOVERY SYSTEM
To clean the vacuum float:
Remove the white retaining clamp from the screen.
Pull the vac screen / float ball assembly off the vac box.
Rinse with hot water. Scrub with a brush if necessary
Dry thoroughly.
Replace vac screen / float ball assembly onto vac box.
Replace and tighten clamp.
BAFFLE ASSEMBLY
The baffle assembly is also located inside the
recovery tank and accessed by opening the re-
covery tank lid. The baffle adds rigidity to the tank
walls and lessens the sloshing of the water inside
the recovery tank.
VACUUM FLOAT
The vacuum float assembly is located inside the
recovery tank and is accessed by opening the re-
covery tank lid. The float assembly stops the flow
of air to the vacuum motor in the event that the
recovery tank is filled to capacity.
DRAIN HOSE
To drain the recovery system we have a poly hose
with an integrated flow control feature. By squeez-
ing the hose you can control the flow of the recov-
ery tank as it is being emptied. The hose cap is
attached to the hose with a tether to help prevent
loosing it.
RETAINING
CLAMP
VAC
SCREEN
Summary of Contents for MINI-MAG SERIES
Page 2: ......
Page 14: ...Mini Mag Service Manual V1 0 1 1 2 MAINTENANCE ...
Page 15: ...Mini Mag Service Manual V1 0 1 1 3 MAINTENANCE ...
Page 16: ...Mini Mag Service Manual V1 0 1 1 4 MAINTENANCE BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 28: ...Mini Mag Service Manual V1 0 3 3 6 SQUEEGEE SYSTEM SQUEEGEE ADJUSTMENT EXAMPLES ...
Page 30: ...Mini Mag Service Manual V1 0 3 3 8 SQUEEGEE SYSTEM ...
Page 42: ...Magnum Service Manual V1 0 6 6 4 SOLUTION SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...