Mini-Mag Service Manual V1.0
13
13-36
CENTRAL COMMAND CONTROLLER
“DRIVE MOTOR” does
not work.
Operate machine
and verify the
customers
complaint.
Does the
drive motor work
properly?
Instruct owner on
proper machine
operation
YES
MiniMAG – TRACTION DRIVE w/CCII
DRIVE MOTOR DIAGNOSTICS
1 of 1
Does
anything else
on the machine
work?
NO
Address machine
not turning on first.
NO
Using a voltmeter set the meter to DC volts.
Connect the ( -) probe of the meter to the ( - )
drive motor terminal and the ( + ) probe of the
meter to the drive motor ( + ) terminal.
Depress the throttle pedal fully and read the
voltage.
Is the
motor receiving
at least
10 volts?
Replace the drive
motor
Using a voltmeter set the meter to DC volts.
On the controller back probe the (+) and (-)
traction motor wires. Depress the throttle
pedal fully and read the voltage.
NO
Block the rear wheels of the machine
and raise the drive wheels off the floor.
YES
Is there
at least 10
volts at the
terminals?
Repair connection between
the controller output and the
drive motor.
YES
Replace controller
NO
YES
Can you
rotate both drive
wheels forward by
Hand at the same
time?
YES
Remove the drive
motor from the
drive assembly
Can you
rotate the drive
wheel by
hand?
Replace the drive
assembly
Summary of Contents for MINI-MAG SERIES
Page 2: ......
Page 14: ...Mini Mag Service Manual V1 0 1 1 2 MAINTENANCE ...
Page 15: ...Mini Mag Service Manual V1 0 1 1 3 MAINTENANCE ...
Page 16: ...Mini Mag Service Manual V1 0 1 1 4 MAINTENANCE BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 28: ...Mini Mag Service Manual V1 0 3 3 6 SQUEEGEE SYSTEM SQUEEGEE ADJUSTMENT EXAMPLES ...
Page 30: ...Mini Mag Service Manual V1 0 3 3 8 SQUEEGEE SYSTEM ...
Page 42: ...Magnum Service Manual V1 0 6 6 4 SOLUTION SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...