CENTRAL COMMAND CONTROLLER
“( + ) BUSS BAR” does
not power up.
Operate machine
and verify the
customers
complaint.
Is the (+)
buss bar receiving
battery voltage?
Instruct owner on
proper machine
operation
YES
MiniMAG – TRACTION DRIVE w/CCII
BUSS RELAY DIAGNOSIS
1 of 2
Does the
machine turn
on?
Go to the “KEY
SWITCH” diagnosis
section
NO
NO
Using a voltmeter set the meter to DC volts.
Connect the ( -) probe of the meter to the ( - )
buss bar with a clip on your meter probe.
With the positive lead of your meter measure
the voltage at terminal #85 (red wire) on the
buss relay with the key on.
Is there
battery voltage at
this terminal?
Repair break in wiring
between Terminal #85 and
the key switch
NO
Using a voltmeter set the meter to DC volts.
Measure the voltage between terminals #85
(red wire) and #86 (black wire) on the buss
relay with the key on.
Is there
battery voltage
across these
terminals?
YES
Using a voltmeter set the meter to DC volts.
Measure the voltage between terminals #85
(red wire) and the negative buss bar with the
key on.
NO
Using a voltmeter set the meter to DC volts.
Connect the ( -) probe of the meter to the ( - )
buss bar with a clip on your meter probe.
With the positive lead of your meter measure
the voltage at terminal #87 (red wire #) on the
buss relay with the key on.
YES
YES
GO TO
Page 2
-A-
GO TO
PAGE 2
-B-
Summary of Contents for MINI-MAG SERIES
Page 2: ......
Page 14: ...Mini Mag Service Manual V1 0 1 1 2 MAINTENANCE ...
Page 15: ...Mini Mag Service Manual V1 0 1 1 3 MAINTENANCE ...
Page 16: ...Mini Mag Service Manual V1 0 1 1 4 MAINTENANCE BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 28: ...Mini Mag Service Manual V1 0 3 3 6 SQUEEGEE SYSTEM SQUEEGEE ADJUSTMENT EXAMPLES ...
Page 30: ...Mini Mag Service Manual V1 0 3 3 8 SQUEEGEE SYSTEM ...
Page 42: ...Magnum Service Manual V1 0 6 6 4 SOLUTION SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...