Mini-Mag Service Manual V1.0
13
13-22
CENTRAL COMMAND CONTROLLER
Vacuum motor will
not run
Test machine /
Verify the
complaint
Advise customer on
proper machine
operation
Does the
vacuum motor
run?
Is the main
power switch
on?
Turn on main
power switch
Is the battery gauge
in the “green zone”
Is the vacuum circuit
breaker popped?
Is the power
indicator lit on the
control panel?
Do you have
power in?
Repair the wiring
from the batteries
to the main power
switch.
Check for power out of the
power switch. Turn the
switch on and off and see if
the switch is functioning.
Is the main power
switch functioning
properly?
Replace the Main
Power switch
NO
YES
NO
YES
YES
NO
YES
Charge batteries
Reset breaker and
test for proper
operation
NO
YES
Check for power
into the main
power switch
NO
YES
Check continuity of
the power input wire
to the batteries
Is there
continuity?
Check condition of
the batteries
Check for ( + ) and
( - ) battery volttage
at the vacuum
motor
NO
Is the main
power switch
on?
Turn on main
power switch
NO
YES
YES
NO
YES
GO TO
PAGE 2
MiniMAG – BRUSH ASSIST
VACUUM MOTOR FLOW CHART
1 of 2
Summary of Contents for MINI-MAG SERIES
Page 2: ......
Page 14: ...Mini Mag Service Manual V1 0 1 1 2 MAINTENANCE ...
Page 15: ...Mini Mag Service Manual V1 0 1 1 3 MAINTENANCE ...
Page 16: ...Mini Mag Service Manual V1 0 1 1 4 MAINTENANCE BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 28: ...Mini Mag Service Manual V1 0 3 3 6 SQUEEGEE SYSTEM SQUEEGEE ADJUSTMENT EXAMPLES ...
Page 30: ...Mini Mag Service Manual V1 0 3 3 8 SQUEEGEE SYSTEM ...
Page 42: ...Magnum Service Manual V1 0 6 6 4 SOLUTION SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...