Mini-Mag Service Manual V1.0
13
13-40
CENTRAL COMMAND CONTROLLER
“VACUUM MOTOR” does
not run.
Operate machine
and verify the
customers
complaint.
Does the motor
work properly?
Instruct owner on
proper machine
operation
YES
Turn on the vac motor switch and
depress foot pedal. Observe the
LCD display to see if the vacuum
icon turns on.
Does the icon
turn on?
See the “VACUUM
SWITCH” section
With a voltmeter set on the DC
setting measure the voltage at
the vacuum motor while the
machine is running and the
vacuum icon is on.
NO
NO
YES
Was there
34 volts or more
at the vacuum
motor?
Replace the
vacuum motor
Using a voltmeter set to the
DC scale back probe the two
lead in the vacuum plug at
the controller while the
machine is running and the
vacuum icon is on
Was there
34 volts or more
at the controller
NO
YES
Replace the
controller
Repair connection
between the vacuum
motor and the controller
YES
NO
MiniMAG – TRACTION DRIVE w/CCII
VACUUM MOTOR FLOW CHART
1 of 1
Summary of Contents for MINI-MAG SERIES
Page 2: ......
Page 14: ...Mini Mag Service Manual V1 0 1 1 2 MAINTENANCE ...
Page 15: ...Mini Mag Service Manual V1 0 1 1 3 MAINTENANCE ...
Page 16: ...Mini Mag Service Manual V1 0 1 1 4 MAINTENANCE BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...
Page 28: ...Mini Mag Service Manual V1 0 3 3 6 SQUEEGEE SYSTEM SQUEEGEE ADJUSTMENT EXAMPLES ...
Page 30: ...Mini Mag Service Manual V1 0 3 3 8 SQUEEGEE SYSTEM ...
Page 42: ...Magnum Service Manual V1 0 6 6 4 SOLUTION SYSTEM BLANK THIS PAGE WAS INTENTIONALLY LEFT BLANK ...