Page
26
with
33
Page
26
with
33
Page
26
with
33
Page
26
with
33
MANUAL - WELDER Fantasy PULSE BI-201
ERROR CODES
In special cases, the display may appear the following messages indicating a problem with the unit. Errors on
the display will appear until you remove the resulting defect.
Error 001 Overload
The device is operated in amounts exceeding its rated
performance. The message may appear
himself
also
in the case of using the wrong diameter extension.
After this message appears, turn off the unit for 5
minutes.
if
after restarting the display is still the
statement
should
contact
the service.
High temperature error 002
The device is equipped with protection against
overheating. Where the installed sensors too high
temperature (eg. Fan failure or blocking), the device
switches off automatically and the display will show the
message.
Error 003 Lock wire feeder
This message appears when you lock the wire feeder.
This can happen when using a wire with a diameter of
0.8 mm for welding of aluminum alloys.