11
INSTALLATION RULES FOR THE ELECTRIC SYSTEM’S SAFETY.
Law n. 186, 1st March 1968.
“Rules for producing and installing electrical and electronic systems, materials, and machines.”
Italian Electro-technical Committee Rule 64-8.
Electric systems operating at a nominal tension non above 1000 V A/C and 1500 V D/C
2.1 TRANSPORT
The machine can be transported via truck, ship, train, and plane.
The machine is usually shipped wrapped in nylon, and the suction engine is dismantled.
All accessories are shipped separately.
2.2 LIFTING AND HANDLING
The machine can be lifted with a crane or freight elevator, using two hooked, clasped tows at least 1 meter
long, or with a fork lift.
If lifted with a crane or freight elevator:
Place the hook end of the tows on top, and in the eyebolt in the lower part (fig. 6), placed in the plates welded
on the exchanger.
WARNING!
Lifting the machine with shorter tows can damage its upper parts.
2.3 ACCESSORIES
The only accessory for the machine is the fumes purifier, available on demand.
FIG.6