5 END OF SERVICE
When the machine’s lifetime is up, you should:
- remove all rubber parts (O-ring, gaskets, girds, etc...).
- remove all recyclable plastic components (thermoplastic parts) and separate them from the
unrecyclable ones (thermo-resistant parts).
- remove all copper parts (cables).
Dispose of the different materials according to your Country’s laws.
6 ACOUSTIC POLLUTION
The sound emission levels for the models F 85 F120 and F240 have been tested according to the
ISO 11202 rules, and the following maximum sound thresholds have been recorded:
LpA (dB(A))
MODEL
F85
F 120
F 240
Machine with only
< 60
< 60
< 60
fumes vent turned on
Machine with only
66,6
70,6
73,4
warm air vent
Machine with both
66,7
70,9
74,1
vents turned on
LpA:
Max sound pressure level recorded on the operator’s work station