Estate Slide E-SL 1200
Programming Gate Movement Variables
Using the following procedures you can change factory settings such as auto close, speed, force, delays and
more.
Begin the programming process by pressing
P1
. Pressing
P1
selects
A,B,C,D or E
. A, B, C, D and E correspond with the
variables in the chart on the following page.
When you are on the desired variable you would like to
change the setting of press
P2
to change the setting of that
variable.
P2
will change the light to 1, 2, 3 or 4 which corre-
spond with the settings on the chart below on the following
page. Below is a list what each variable controls.
A
: Switches between Function Logics. Function Logics are sets of actions that will occur when an accessory ter-
minal connection is made or disrupted. Each set of actions is designed to give different results providing increased
safety, convenience or other.
B
: Switches between the amount of time the gate pauses before closing after reaching full open. By selecting
Logic EP (4) all pause times will be void and the gate will remain open until an opening devices is triggered.
C
: Adjusts the partial opening width.
D
: Switches between the amount of force the gate opener will exert before an obstruction is detected and the
gate reverses directions.
E
: Switches between the speed of the gate motion. This does not effect the soft start and stop.
See the following page for Gate Movement Variables LED Chart.