Estate Slide E-SL 1200
Control Board Pre-Learning Preparations
For your opener to function properly a few connections must be made prior to the learning process. Accessories
should NOT be installed until after the learning process is completed.
1.
Using the provided orange jumper wire, connect the normally closed safety terminals (terminal 3, 4, and 5) to one
of the negative terminals (terminals 12, 13, 14, or 15). We recommend that these jumpers are later replaced with
safety devices after learning is complete.
2.
Connect the power last
. First connect the battery to the control board and then contact the power
supply to J2 on the control board.
3.
Your connections can be checked using the diagnostics mode
. Press
P2 once
. One a single gate opener oper-
ation C, D, and E should be lit. After checking, press P2 again to exit diagnostics mode. To learn more about diag-
nostics see section 15.1.
!