Estate Slide E-SL 1200
Simple Diagnostics
Diagnostics using the Power light on your Master Control
Board.
The
P
light has a diagnostic function. There are 4 statuses.
1.
Steady light indicating main power is ON and the battery
is charged.
2.
Flashing slowly (lights every second) indicates no main
power but the battery is charged.
3.
Flashing quickly (lights every 1/4 of a second) indicates
main power on but discharged battery
4.
Light OFF indicates no main power and discharged bat-
tery.
Status of accessory inputs.
The Master Control Board has the ability to verify the status of the terminal board inputs. To access this function:
When all LEDs are off (both lettered and numbered) press
P2
. The statuses of the accessory terminals in the following
chart will be shown in the lettered LEDs column.
LED ON = Closed Contact
LED OFF = Open Contact
When you have finished
checking, press
P2
again to
exit.
If you do not , the LED sta-
tus check will stay active for
5 minutes and then the board
returns to all LEDs Off.
Warning: When you access
the input status function,
all accessories are powered,
even with the gate idle. P1
is active and can be used to
open and close the gate.
Normal Operation
idle LED lights
LED
ON
OFF
A = OFF
A = Terminal 1,
Open/Close Function
Opening/Closing de-
vice is triggered
Opening/Closing de-
vice is not triggered
B = OFF
B = Terminal 2, Sin-
gle leaf open / close
Opening/Closing de-
vice is triggered
Opening/Closing de-
vice is not triggered
C = ON
C = Terminal 3, Stop
Command
Motion stop device is
in place and not trig-
gered or jumper is in
place
Motion stop device
has been triggered or
is not connected
D = ON
D = Terminal 4.
Opening safety device
Motion stop device is
in place and not trig-
gered or jumper is in
place
Safety device has
been triggered or is
not connected
E = ON
E = Terminal 5, Clos-
ing safety device
Motion stop device is
in place and not trig-
gered or jumper is in
place
Safety device has
been triggered or is
not connected
1 = OFF if closed or
open, ON if not
1 = Sensor
Sensor is not tripped
Sensor is tripped
15.1