10 FUNCTION LOGICS

LOGIC  “E”

PULSES

STATUS OF THE  

AUTOMATED SYSTEM

OPEN 

FSW CL

FSW OP

STOP

CLOSED

opens 

(1)

no effect

(function 

Ad

 excluded)

no effect

(inhibits opening)

no effect

(inhibits opening)

OPENING

stops operation 

no effect

see 

programming

stops operation 

OPEN

closes 

(1)

no effect

(function 

Ad

 excluded)

no effect

stops operation 

CLOSING

reverses immediately  

at opening 

reverses immediately  

at opening 

no effect

stops operation 

STOPPED

closes 

(1)

inhibits closing

no effect

no effect

(inhibits opening)

LOGIC  “EP”

PULSES

STATUS OF THE  

AUTOMATED SYSTEM

OPEN 

FSW CL

FSW OP

STOP

CLOSED

opens 

(1)

no effect

(function 

Ad

 excluded)

no effect

(inhibits opening)

no effect

(inhibits opening)

OPENING

stops operation 

no effect

see 

programming

stops operation 

OPEN

closes 

(1)

no effect

(function 

Ad

 excluded)

no effect

stops operation 

CLOSING

stops operation 

reverses immediately  

at opening 

no effect

stops operation 

STOPPED

restarts in opposite 

direction (always closes 

after a Stop)

inhibits closing

no effect

no effect

(inhibits opening)

(1)

 

With pre-flashing selected, movement begins after the set pre-flashing time.

When the Encoder is tripped, this causes stop at opening and reverse at closing.

Tab. 4/c

Tab. 4/d

LOGIC  “A”

PULSES

STATUS OF THE  

AUTOMATED SYSTEM

OPEN 

FSW CL

FSW OP

STOP

CLOSED

opens and closes again 

after pause time

 (1)

no effect

(function 

Ad

 excluded)

no effect

(inhibits opening)

no effect

(inhibits opening)

OPENING

no effect

no effect

see 

programming

stops operation 

OPEN IN PAUSE

recharges pause time

no effect

(inhibits closing)

no effect

stops operation 

CLOSING

reverses immediately  

at opening 

reverses immediately  

at opening 

no effect

stops operation 

STOPPED

closes 

(1)

no effect

(inhibits closing)

no effect

no effect

(inhibits opening)

LOGIC  “AP”

PULSES

STATUS OF THE  

AUTOMATED SYSTEM

OPEN 

FSW CL

FSW OP

STOP

CLOSED

opens and closes again 

after pause time

 (1)

no effect

(function 

Ad

 excluded)

nessun effetto

(inibisce apertura)

no effect

(inhibits opening)

OPENING

stops operation 

no effect

see 

programming

stops operation 

OPEN IN PAUSE

stops operation 

no effect

(inhibits closing)

no effect

stops operation 

CLOSING

reverses immediately  

at opening 

reverses immediately  

at opening 

no effect

stops operation 

STOPPED

closes 

(1)

no effect

(inhibits closing)

no effect

no effect

(inhibits opening)

Summary of Contents for E550

Page 1: ...E550...

Page 2: ...ety of people it is important that you read all the following instructions Incorrect installation or incorrect use of the product could cause serious harm to people Carefully read the instructions bef...

Page 3: ...r Coupling to 5 pin Minidec board Decoder Receiver RP RP2 Terminal board inputs removable Open Encoder Opening safety devices Closing safety devices Opening limit switch Closing limit switch Flashing...

Page 4: ...creasing the system s safety level If the Failsafe control isdisabled theterminalisanegativeforsupplytoaccessories 5 FCA Opening Limit switches contact N C The opening limit switch consists of a micro...

Page 5: ...facing the board Insert and remove the board ONLY after cutting power A two digit display is installed on the board During normal operation it indicates the status of the inputs We show below the exa...

Page 6: ...puts status The following table Tab 2 indicates the sequence of functions accessible in BASIC PROGRAMMING Tab 2 7 3 ROTATION DIRECTION CHECK Procedure for checking exact connection of motor phases 1 P...

Page 7: ...etely 11 Wait for the motor to stop 12 Take a note of the value indicated on the display as the value of parameter P2 for subsequent input e g P2 32 13 Input values P1 and P2 which you had annotated i...

Page 8: ...closing from 01 to 50 30 F1 CLOSING FORCE IN ZONE A Adjusts force during closing from 01 to 50 20 S2 CLOSING SPEED IN ZONE B Adjusts closing speed in zone B from 01 to 10 10 max speed 01 min speed 05...

Page 9: ...8 AUTOMATED SYSTEM TEST When you have finished programming check if the system is operating correctly Check if force is adequately adjusted and if the safety devices operate correctly Also run the imp...

Page 10: ...h pre flashing selected movement begins after the set pre flashing time When the Encoder is tripped this causes stop at opening and reverse at closing Tab 4 c Tab 4 d LOGIC A PULSES STATUS OF THE AUTO...

Page 11: ......

Page 12: ...com au INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com SWITZERLAND FAAC AG Altdorf Switzerland tel 41 41 8713440 www faac ch CHINA FAAC SHANGHAI Shanghai China te...

Reviews: