6
ENGLISH
Fig. 5
Fig. 6
As it moves, and according to its position, the up-and-over door requires different force, speed and sensitivity. This
control board is provided with independent adjustment of parameters (
F1
,
S1
,
E1
,
F2
,
S2
,
E2
) during closing, between
the top (zone B) and bottom (zone A) of the door.
To pick out the two zones A and B, point X must be located; refer to Fig. 5 or 6.
1) Release the operator.
2) Position the up-and-over door at 30°.
3) To facilitate positioning the door at 30°, use the positioning template, located at the end of this manual.
4) Locate and mark point X as shown in Fig. 5 or 6.
5) Close the door by hand, relock the operator and power up the system.
6) Access ADVANCED PROGRAMMING with push-buttons
F
and
+
, and display the first function (
Po
).
7) Give an OPEN command, open the door electrically, inclining it until you reach the coincidence with point X.
8) Stop the door with another OPEN command.
9) Take a note of the value indicated on the display as the value of parameter
P1
, for subsequent input (e.g.
P1
=
20
).
10) Give an OPEN command, and open the door completely.
11) Wait for the motor to stop.
12) Take a note of the value indicated on the display as the value of parameter
P2
, for subsequent input (e.g.
P2
=
32
).
13) Input values
P1
and
P2
which you had annotated in the ADVANCED PROGRAMMING parameters.
Run the impact curve test and, if necessary, modify values
F1
,
S1
,
E1
,
F2
,
S2
,
E2
in order to respect current legal
regulations.
7.5 IDENTIFYING THE DOOR POSITION LIMITS
7.4 ADVANCED PROGRAMMING
To access ADVANCED PROGRAMMING, use push-button
F and +
:
1) press push-button
F
and, while holding it down, press push-button
+
.
2) if you release the push-button
+
, the display shows the name of the first function (
PO
).
3) if you release the
F
push-button, the display shows the value of the function, which can be changed with keys
+
and
-
.
4) if you press
F
again (and hold it down), the display shows the name of the next function, etc.
5) when you reach the last function, press the
F
push-button to exit programming, and the display resumes showing
the inputs status (see chapter 6).
6) At any point of ADVANCED PROGRAMMING, you can save the modifications and exit directly by pressing push-button
F
and, while holding it down, simultaneously pressing push-button
-
.
The following table (Tab.3) indicates the sequence of functions accessible in ADVANCED PROGRAMMING.
Summary of Contents for E550