8 = FSW CL = Closing Safety devices contact (N.C.)

Safety devices are all devices (photocells, sensitive ed-

ges,…) with N.C. contact, which, if there is an obstacle 

in the area they protect, operate to reverse door closing 

movement. They have no effect during the opening sta-

ge, except in the Ad function (see chap.7.4. - Advanced 

programming).

If the closing safety devices are engaged while the door 

is open, they inhibit any Open pulse.

To install several safety devices, connect the N.C. contacts 

in series.

 

If no closing safety devices are connected, 

jumper connect “FSW CL” to terminal 4.

9 = ENCODER = Input for encoder signal.

The signal received from the encoder must be connected 

to this terminal. To supply power to the encoder, connect 

the remaining two wires to terminals “1 - 3” observing the 

polarity indicated on the lay-out of Fig. 2.

      

The control unit will not operate without an encoder. 

  

For two-motor applications, the encoder must 

be applied only to motor 1 (the one with the 

board).

10 = OPEN = OPEN Command (N.O.)

Any device (push-button, detector,…) which, by closing a 

contact, supplies an opening pulse to the door.

To install several Open devices, connect N.O. contacts 

in parallel.

STOP = STOP command (N.C.)

A suitable device which, by opening a contact, immediately  

stops door movement. Connect the 

STOP

 in series to the 

common contact of the limit switches (see Fig 2) If a 

STOP

 

Push-button cannot be connected, connect the common 

contact of the limit switches to terminal 

2

. To install several 

STOP

 devices, connect N.C. contacts in series.

5.1.4. CONNECTOR J4 (low voltage)

Connector J4 (Fig. 4) is used for rapid connection of Minidec,  

Decoder  and  RP  Receivers.  The  receiver/decoding 

board must be inserted with the components facing the 

board.

   

 

Insert and remove the board ONLY after cutting 

power.

A two-digit display is installed on the board. During normal 

operation, it indicates the status of the inputs. We show 

below the exact correspondence between the horizontal  

segments  (we  will  call  them  LEDs  from  now  on)  of  the 

display and the inputs.

The table below indicates the status of the LEDs in relation 

to the status of the inputs.

Tab.1   STATUS OF LEDS

LED

ON

OFF

OPEN

Opening command active 

O p e n i n g   c o m m a n d  
inactive

ENCODER

LED flashes during operation 

FSW OP

Opening safety devices 
released

Opening  safety  devices 
engaged

FSW CL

Closing safety devices 
released

Closing  safety  devices 
engaged

FCA

Opening limit switch  
free

Opening limit switch  
engaged

FCC

Closing limit switch free

Closing limit switch  
engaged

Led on 

= closed contact 

/ led off = 

open contact

 

6 SIGNALLING LEDS (status of inputs)

An example of the 

connection of the 

radio receiver

Fig. 4

7 PROGRAMMING 

Power up the system, checking that no pulse 

generator is active and can send an OPEN 

command.

 

With this control board, you can adjust the force, speed 

and  sensitivity  parameters  in  compliance  with  what  is  

specified  by  current  regulations  to  respect  the  impact 

curve.  (see paragraph 7.2).

To program the operation of the automated system, you 

must access the “PROGRAMMING” mode. 

Programming is in two parts: BASIC PROGRAMMING and 

ADVANCED PROGRAMMING.

 

modification of the programming  

parameters is immediately effective, 

whereas definitive memory-storage  

occurs only on exiting programming and 

returning to the view of the status of the 

automated system. If you cut power to 

the board before returning to view the 

status, all the modifications made will 

be lost.

 You can return to viewing the status from 

any point of programming at any level, 

by pressing keys F and - simultaneously.

: The statuses of the LEDs with door closed and 

at rest are highlighted in 

bold

.

Summary of Contents for E550

Page 1: ...E550...

Page 2: ...ety of people it is important that you read all the following instructions Incorrect installation or incorrect use of the product could cause serious harm to people Carefully read the instructions bef...

Page 3: ...r Coupling to 5 pin Minidec board Decoder Receiver RP RP2 Terminal board inputs removable Open Encoder Opening safety devices Closing safety devices Opening limit switch Closing limit switch Flashing...

Page 4: ...creasing the system s safety level If the Failsafe control isdisabled theterminalisanegativeforsupplytoaccessories 5 FCA Opening Limit switches contact N C The opening limit switch consists of a micro...

Page 5: ...facing the board Insert and remove the board ONLY after cutting power A two digit display is installed on the board During normal operation it indicates the status of the inputs We show below the exa...

Page 6: ...puts status The following table Tab 2 indicates the sequence of functions accessible in BASIC PROGRAMMING Tab 2 7 3 ROTATION DIRECTION CHECK Procedure for checking exact connection of motor phases 1 P...

Page 7: ...etely 11 Wait for the motor to stop 12 Take a note of the value indicated on the display as the value of parameter P2 for subsequent input e g P2 32 13 Input values P1 and P2 which you had annotated i...

Page 8: ...closing from 01 to 50 30 F1 CLOSING FORCE IN ZONE A Adjusts force during closing from 01 to 50 20 S2 CLOSING SPEED IN ZONE B Adjusts closing speed in zone B from 01 to 10 10 max speed 01 min speed 05...

Page 9: ...8 AUTOMATED SYSTEM TEST When you have finished programming check if the system is operating correctly Check if force is adequately adjusted and if the safety devices operate correctly Also run the imp...

Page 10: ...h pre flashing selected movement begins after the set pre flashing time When the Encoder is tripped this causes stop at opening and reverse at closing Tab 4 c Tab 4 d LOGIC A PULSES STATUS OF THE AUTO...