E1SL
37
532258 04 - Rev. B
Tr
ansla
tion of the original instruc
tions
ENGLISH
Errors and Warnings
(codes on grey background = warnings)
Required action (perform
RESET
after the intervention)
53
CYCLES NUMBER CORRUPTED
Replace the board and carry out maintenance on the system.
54
LOCK HW FAULT
Perform
RESET
. Check the motor block.
55
PHARMACY MODE IN PROGRESS
PHARMACY OPEN is in progress.
56
BATTERY OPERATION
The warning remains as long as the automation operates on the battery with mains power supply down.
57
SEARCHING FOR OPENING STOP IN PROGRESS
The indication remains as long as the stage is ongoing.
58
SEARCHING FOR CLOSING STOP IN PROGRESS
The indication remains as long as the stage is ongoing.
59
LOCK FAULT (SURVEILLANCE KIT)
Perform
RESET
. If the problem persists, replace the motor block.
60
MAINTENANCE REQUEST
Carry out ordinary or periodic scheduled maintenance.
61
SDK EVO / LK EVO/ KS EVO FAULT
Check it is the correct device and check the SDK EVO / LK EVO/KS EVO connections. Update FW. If the
problem persists, replace the SDK EVO / LK EVO / KS EVO.
62
BATTERY CHARGER FAILURE
Perform
RESET
. If the problem persists, replace the board.
63
INTRUSION
An attempt to open the automation is in progress.
65
SETUP
IN PROGRESS
SETUP
is in progress.
66
MOVEMENT WITH MOTOR2 IS IN PROGRESS
The second Motor is in operation.
67
SLEEP
Low power mode is in progress: to prevent the emergency battery from being discharged, power to the ac-
cessories is switched off apart from to the SDK EVO.
68
SAFETIES TEST FAILED
The TEST on inputs configured as safeties has failed. In this condition, the automation moves at a slower
speed. Check that the safety detector is working. If the problem persists, replace the device.
69
DOOR OPEN SEMI-AUTOMATIC OPEN
Door is open from SEMI-AUTOMATIC OPEN input.
70
BATTERY DISCHARGED
The emergency battery has a low charge level.
71
INTERCOM
The automation is in INTERCOM mode.
72
INTERCOM FAULT
No communication between the
Master
and
Slave
nodes.
73
INTERLOCK FUNCTION ACTIVE
The automation is in INTERLOCK mode.
74
INTERLOCK FUNCTION IN PROGRESS
MODFUN INTERLOCK is running.
75
INTERCOM SLAVE NODE in MAINTENANCE MANUAL/LOCAL The INTERCOM board has been put in maintenance mode.
77
INTERCOM REGISTRATION IN PROGRESS
The automation is the
MASTER
and is registering the nodes.
78
AIRSLIDE IN PROGRESS
The automation is in AIRSLIDE mode.
79
INTERLEAVES IN PROGRESS
The automation is in INTERLEAVES mode.
80
NON-STANDARD PROGRAMMING
Non Standard configuration in use.
81
UPDATE FILES MISSING FROM USB
Check for files on the USB memory device.
82
FILE WRITING ERROR
Download the files to the USB storage device again.
83
DEVICE BEING UPDATED INCORRECT OR MISSING
The connected device on which you are attempting to update the FW is not compatible or not connected.
84
FW UPDATE ERROR
File read error. Repeat update from USB.
88
FILE READ ERROR
File corrupted or not the right one, device to be updated.
90
PASSWORD ERROR
Password file different to the one on the board.
91
BOARD FAILURE
Replace board.
96
Microcontroller fault
Replace board.
97
USB ERROR
USB device not recognised, not formatted with the FAT or FAT 32 file system, or faulty.
99
BOARD DATA DELETION IN PROGRESS
Wait for the data deletion procedure to finish.
101
FW FAULT SDK EVO
Carry out the
RESET
procedure. If the error persists, replace the SDK EVO.
102
SDK EVO FAILURE
Carry out the
RESET
procedure. If the error persists, replace the SDK EVO.
103
SDK EVOLANGUAGE LOADING ERROR
Carry out the
RESET
procedure.
If
the error persists replace the SDK EVO.
104
SDK EVO FW ERROR
Update the SDK EVO firmware.
105
BOARD COMMUNICATION ERROR
Check the connections. If the error persists, the communication channel of the board, the SDK EVO, or both
are damaged. Replace the board or the SDK EVO.
106
SDK EVO CONNECTED TO A BOARD THAT IS NOT RECOG-
NISED
Check the type of board.
Summary of Contents for E1SL
Page 51: ...E1SL 51 53225804 Rev B...