11
E1SL
23
532258 04 - Rev. B
DL11
J13
V G
S1
G
T
J1
V RX
TX G
J8
E1 G E
2
J7
T1 G
T2
R1
G R2
J9
V G 01 02 02
J22
J21
V
G
I1
I2
G
I3
I4
V
J18
G CH CL
G
V G
S2
G
T
J4
J13
1
2
3 4
5
1
2 3
2
C
B
C
D
B
A
1 2 3 4 5
J13
Tr
ansla
tion of the original instruc
tions
ENGLISH
XB LOCK and monitoring connection (optional)
EMERGENCY BATTERY
The battery kit allows the automation to operate in case of mains
power failure.
To conserve battery power, the board activates the LOW POWER
mode: it turns off power to the accessories apart from the SDK EVO
(to which it disables the backlighting), it DOES NOT carry out the
PULL & GO function, if enabled. The board maintains the battery
charge, but does not charge batteries that are completely discharged.
1. Connect the emergency battery kit.
J14
Emergency battery connection
2. Enable the battery, specifying the IMMEDIATE movement per-
formed (then the operation stops) or that is performed as the
LAST MOVEMENT (the automation continues to operate as long
as the battery has sufficient charge. If the battery discharges, it
performs this movement and then stops).
-
from Board
, Advanced Programming:
bA
in all Operating Modes apart from NIGHT-TIME
no
= not enabled
1
= OPENS IMMEDIATELY
2
= CLOSES IMMEDIATELY
3
= LAST MOVEMENT OPENING
4
= LAST MOVEMENT CLOSING
bn
in NIGHT-TIME mode (see options
bA
)
or
-
from SDK EVO
:
/
PROGRAMMING
/
BATTERY KIT
…
…
FUNCTION
:
DISABLED
,
UNTIL LAST MOVEMENT
,
LAST MOVEMENT ONLY
…
LAST MOVEMENT
:
OPENING
,
CLOSING
NIGHT MODE
:
LAST MOVEMENT ONLY
,
UNTIL LAST MOVEMENT
…
LAST MOVEMENT NIGHT
:
OPENING
,
CLOSING
XB LOCK MOTOR BLOCK AND MONITORING (OPTIONAL)
The motor block allows the leaves to be locked mechanically.
The motor block is never engaged in MANUAL mode.
If there is a power failure, the position of the XB LOCK remains un-
changed. When the automation is operating on battery, the motor
block is only active in NIGHT mode (operation can only be modified
via the SDK EVO).
!
Always turn off the mains power supply and disconnect the emergency
battery (if present) before connecting or disconnecting the motor block.
1. Install the motor block following the installation instructions.
2. Connect the motor block to the E1SL board using the connector (
A
).
3. If installed, connect the monitoring device (
B
) to the terminal
board of the motor block.
4. During programming, assign the motor block function and enable
monitoring, if installed.
-
from Board
, Advanced Programming:
EL
=
1
…
5
;
SU
=
Y
(if monitoring is installed)
or
-
from SDK EVO
:
/
PROGRAMMING
/
KIT LOCK
…
…
TYPE
XB LOCK
…
FUNCTION
…
SURVEILLANCE KIT
…
BATT. FUNCTION
8. ACCESSORIES
MOTOR BLOCK FUNCTION
:
DISABLED
(
EL
=
0
): not active
NIGHT
(
EL
=
1
): with the automation in NIGHT mode, locks the closed leaves and
the open leaves with the Pharmacy Open command
NIGHT + MONODIR
(
EL
=
2
):
NIGHT
+
with the automation in ENTRY ONLY / EXIT
ONLY mode, locks the closed leaves
NIGHT + OPENED
(
EL
=
3
):
NIGHT
+ with the automation in any mode (apart from
MANUAL), always locks the open leaves
NIGHT + CLOSED
(
EL
=
4
):
NIGHT
+
with the automation in any mode (apart from
MANUAL), always locks the closed leaves
ALWAYS
(
EL
=
5
): with the automation in any mode (apart from MANUAL), locks
the leaves after any opening / closing movement
Motor block operation when the automation is operating on battery
:
- from SDK EVO …
KIT LOCK
/
BATT. FUNCTION
NIGHT
: active only as
NIGHT
(DEFAULT)
STANDARD
: maintains the programmed function (
EL
or …
KIT LOCK
/
FUNCTION
)
ALWAYS OPEN
: the automation never locks the leaves irrespective of the mode
1
green
B
Motor block monitoring (IF INSTALLED)
2
pink
C
Manual release microswitch
3
yellow
4
white
D
Motor block coil (connected at the factory)
5
brown
Summary of Contents for E1SL
Page 51: ...E1SL 51 53225804 Rev B...