E1SL
18
532258 04 - Rev. B
Tr
ansla
tion of the original instruc
tions
ENGLISH
7
ADVANCED programming
ADVANCED Function
Default:
A1000 A1400 AIR RKE 1400 SF1400 GBF1500
P1
INPUT S1 configuration
(see
options
C1
)
20
20
20
20
20
1F
INPUT S1 TEST
Displayed only if the input is configured as safety
(
P1
=
20
or
21
or
23
)
Y
= TEST enabled
no
= TEST not enabled
Y
Y
Y
Y
y
P2
INPUT S2 configuration
(see
options
C1
)
20
20
20
20
20
2F
INPUT S2 TEST
Displayed only if the input is configured as Safety (
P2
=
20
or
21
or
23
)
Y
= TEST enabled
no
= TEST not enabled
Y
Y
Y
Y
y
Ot
OPERATION OF SAFETIES IN OPENING
1
= STOP (stops the opening)
2
= Low Energy (slow movement)
2
2
2
2
2
bP
BUTTON PHOTOCELLS
The TEST is NOT available for these photocells.
no
= no photocell
1
= 1 pair of photocells
2
= 2 pairs of photocells
no
no
no
no
no
E1
INPUT E1 configuration
(see
options
C1
)
no
no
no
no
no
1F
INPUT E1 TEST
Displayed only if the input is configured as Safety
(
E1
=
20
or
21
or
23
)
.
Y
= TEST enabled
no
= TEST not enabled
no
no
no
no
no
E2
INPUT E2
configuration (see
options
C1
)
no
no
no
no
no
2F
INPUT E2 TEST
Displayed only if the input is configured as Safety (
E2
=
20
or
21
or
23
)
Y
= TEST enabled
no
= TEST not enabled
no
no
no
no
no
bA
BATTERY KIT
Operation of the emergency battery NOT in NIGHT-TIME mode.
no
= not enabled
1
= OPENS immediately
2
= CLOSES immediately
3
= with flat battery last movement OPENING
4
= with discharged battery last movement CLOSING
no
no
no
no
no
bn
NIGHT BATTERY KIT
Operation of the emergency battery in NIGHT-TIME operating mode. Displayed only if
the Battery Kit is enabled (
bA
other than
no
)
.
(see options
bA
)
4
4
4
4
4
EL
MOTOR BLOCK XB LOCK / XM LOCK
XM LOCK options not displayed for A1000 (
CF
=
1
)
no
no
no
no
no
no
= not enabled
1
= XB LOCK closed in NIGHT-TIME mode
2
= XB LOCK closed in ENTRY ONLY, EXIT ONLY, NIGHT-
TIME mode
3
= XB LOCK closed in NIGHT-TIME mode and with
leaves open
4
= XB LOCK closed in NIGHT-TIME mode and with
leaves closed
5
= XB LOCK closed at the end of each movement
6
= XM LOCK closed in NIGHT-TIME mode
7
= XM LOCK closed in ENTRY ONLY, EXIT ONLY, NIGHT-
TIME mode
8
= XM LOCK closed in NIGHT-TIME mode and with
leaves open
9
= XM LOCK closed in NIGHT-TIME mode and with
leaves closed
10
= XM LOCK closed at the end of each movement
SU
MONITORING of XB LOCK / XM LOCK
no
= not enabled
Y
= enabled
no
no
no
no
no
dM
DOUBLE MOTOR KIT ACTIVATION
no
= second motor kit not enabled
Y
= second motor kit enabled - NOT displayed for SF1400 (
CF
=
4
) or for GBF1500 (
CF
=
5
)
-
no
no
no
-
nd
NIGHT-TIME MODE DELAY
0
…
90
s Adjustment step = 1 s
10
10
10
10
10