E1SL
16
532258 04 - Rev. B
Tr
ansla
tion of the original instruc
tions
ENGLISH
6
BASIC Programming
BASIC Function
Default:
A1000 A1400 AIR RKE 1400 SF1400 GBF1500
CF
Automation model
If this parameter is modified, the relative default configuration is loaded.
1
2
3
4
5
no
= no selection (factory default)
1
= A1000
2
= A1400 AIR
3
= RKE 1400 (for SLIDING FHE )
4
= SF1400
5
= GBF1500
dF
DEFAULT configuration
Indicates whether the programming corresponds to the default settings for the
automation model and allows you to reload the defaults.
no
= at least 1 parameter has been modified. If you wish to reload the default values, select
Y
Y
= programming corresponds to the default settings
Y
Y
Y
Y
Y
Ln
Leaf number
- displayed only for SF1400 (
CF
=
4
) If modified you have to perform the
SETUP
.
1
= 1 leaf
2
= 2 leaves
-
-
-
2
-
Lt
Select passage opening
- displayed only for SF1400 (
CF
=
4
)
1
= narrow opening width: max 65 cm (with 1 leaf), max 130 cm (with 2 leaves)
2
= average opening width: 65…75 cm (with 1 leaf), 130…150 cm (with 2 leaves)
3
= wide opening width: greater than 75 cm (with 1 leaf), greater than 150 cm (with 2 leaves)
-
-
-
2
-
rM
Direction of rotation of the motor
If it is modified you have to perform the
SETUP
.
1
= STANDARD
rotation
-1
= NON STANDARD rotation
1
1
1
1
1
PO
Partial Open
- NOT displayed for SF1400 (
CF
=
4
) or for GBF1500 (
CF
=
5
)
no
= 100%
20
…
95
% Adjustment step = 5%
50
50
50
-
-
PA
Pause time
before closing again in automatic operation mode
0
…
30
s Adjustment step = 1 s
2
2
2
2
2
ES
Energy Saving
no
= not enabled
Y
= enabled
no
no
no
no
no
Pn
Night pause time
In Night mode, after being opened via the Key command, the door remains open for the
length of time set (
0
s …
4.0
min)
0
…
58
s Adjustment step = 2 s
1.0
…
4.0
min Adjustment step = 10 s (e.g.
1.2
= 1 min and 20 s)
10
10
10
10
10
cS
Closing speed
level
1
…
10
5
5
5
5
1
oS
Opening speed
level
1
…
10
10
8
8
5
3
cF
Closing force
level
1
…
10
5
5
5
5
5
oF
Opening force
level
1
…
10
8
8
10
8
5
tF
Force time on obstacle for CF and OF
0.1
…
3.0
s Adjustment step = 0.1 s
1.0
1.0
2.0
1.0
1.0
dr
Deceleration ramp when OP and CL
level
1
…
10
6
6
6
4
5
Ar
Acceleration ramp when OP and CL
level
1
…
10
8
8
5
8
5