FAAC E1SL Manual Download Page 33

E1SL 

33 

532258   04     -  Rev.  B

Tr

ansla

tion of the original instruc

tions

ENGLISH

10.  FW UPDATES AND FILE DOWNLOAD - USB

FAAC provides updated firmware in a package called ZIPACK, which 
contains the files in versions that are compatible with one another.  In 
order to be used, the files must be saved to the root directory of a 
USB storage device (not in a folder or zip file and without the original 
names being changed).

Use a USB memory device that has a maximum power consumption of 
500 mA and formatted with the FAT or FAT 32 file system.  The NTFS 
format is not recognised by the board.

AUTOUPDATE

This procedure is available starting from Bootloader version 2.0.

 

For boards with previous versions, carry out the manual update pro-
cedure from the Upload / Download Menu.
1.  With the board switched on, insert the USB memory device into 

connector J17, then press and release the 

RESET

 button.

(alternatively, with the board switched off, insert the USB memory 
device into connector J17 and then switch on the board).

2. 

bo

 will appear on the display:  the board automatically loads all 

the files that are needed to update the board and all the connected 
accessories from the USB storage device.

 

-

--

  appears on the display while the board is being updated, 

then, when the update has finished, it reverts to displaying 

bo

the display then switches to the FW version and then to the door 
status display.  (It is possible to access the Upload/Download 
menu by pressing and releasing the 

F

 button within 3 s from 

when 

bo

 appears on the display).

It is not necessary to remove the USB storage device.

UPLOAD/DOWNLOAD MENU

1.  With the board switched on, insert the USB memory device into 

connector J17, then press and release the 

RESET

 button.

(alternatively, if the board is switched off, insert the USB memory 
device into connector J17 and then switch on the board).

2. 

bo

 appears on the display and the USB led turns on.

3.  Press and release the 

F

 button to scroll through the Upload / 

Download Menu options (see relative table).

Upload operations (updating or loading settings)

Press and hold the 

+

 and 

 buttons simultaneously for at least 3 

seconds in order to carry out the procedure displayed.

 

-

the update starts: 

--

 flashes on the display.

 

Release the but-

tons.

 

-

The procedure is complete when 

Y

 appears on the display.

If there are errors 

no

 appears on the display and the red ERR led is 

lit.  To display the error code, press the 

+

 and 

buttons simultane-

ously.  The errors are described in the Diagnostics Section. 

 

-

Press 

F

 to return to the menu.

When finished, remove the USB storage device. 

Download operations (saving files from board to USB)

Press and hold down the 

+

 and 

 buttons simultaneously for at least 

3 seconds in order to run the function displayed, until 

Or

 appears on 

the display.
Release the buttons and use the 

+

 or 

 buttons to select the method 

for saving the file to the root of the USB storage device: 

Or

 (over-

write) or 

Ad

 (add).

Press 

F

 to confirm.

 

-

The procedure is complete when 

Y

 appears on the display.

If there are errors 

no

 appears on the display and the red ERR led is 

lit.  To display the error code, press the 

+

 and 

buttons simultane-

ously.  The errors are described in the Diagnostics Section. 

 

-

Press 

F

 to return to the menu.

When finished, remove the USB storage device.

Files in the ZIPACK

Bootloader 

1.0 and later

Bootloader

0.5

board firmware (

UP

)

E1SL_xx.hex

1400.hex

KS EVO firmware  (

UE

)

KS_xx.hex

KS EVO.hex

LK EVO firmware  (

UE

)

LK_xx.hex

LK EVO.hex

SDK EVO firmware  (

UE

)

SDK_xx.hex

SDK EVO.hex

SDK EVO languages  (

UE

)

SDKL_xx.bin

SDK EVO_L.bin

Files saved from the board

Bootloader 

1.0 and later

Bootloader

0.5

programming (

UC

 

dC

)

(

*

)

E1SL.prg

1400.prg

programming 

TIMER

 (

Ut

 

dt

(

*

)

)

E1SL.tmr

1400.tmr

LOG file  (

dL

)

(

*

)

E1SL.log

1400.log

(

*

The 

Or

 mode saves the file without a suffix and overwrites any 

existing file with the same name in the USB memory (e.g. E1SL.prg).
The 

Ad

 mode saves the file by adding a 2-digit suffix to the name (e.g. 

E1SL00.prg) and if there is already a file with the same name in the 
root of the USB storage device, the number of the suffix is incremented 
(e.g. E1SL01.prg and so on). 

Note

: the suffix must be deleted if you 

wish to load the file from the UPLOAD MENU.
The .LOG file contains the record of board events, it can be read using 
a text editor.

Files saved from a board with bootloader version 0.5 cannot be loaded 
onto a board with bootloader 1.0 or later, and vice versa.

BOOTLOADER AND FW VERSIONS

SDK EVO allows the firmware versions (

APP

) of the SDK EVO, the 

E1SL board, the DM board, if the DM KIT is installed, and the installed 
devices to be displayed.

 

SDK EVO

/

INFO

 9 

Upload/Download Menu

UP

Board FW update

UE

SDK EVO, LK EVO, KS EVO firmware update including translations of messages 
displayed by the device

UC

Load the E1SL board programming.

Ut

Load the 

TIMER

 programming

dC

Save the board programming

dt

Save the board’s 

TIMER

 configuration 

(

*

)

dL

Save the LOG file of the board (event records, Warnings, Errors)

Summary of Contents for E1SL

Page 1: ...E1SL SDK EVO LK EVO KS EVO E1SL FW 3 4 SDK EVO FW 3 4 LK EVO FW 1 3 KS EVO FW 1 0 This document contains updated instructions starting from the FW versions indicated EN...

Page 2: ...leurs fabricants respectifs Les clients peuvent faire des copies pour leur usage exclusif Ce manuel a t publi en 2018 Copyright FAAC S p A ab dem 2018 Alle Rechte vorbehalten Kein Teil dieses Handbuch...

Page 3: ...ow Energy 20 7 8 Intrusion 20 KEEP CLOSED 20 PULL GO 20 7 9 Energy Saving 20 7 10 Timing and partial opening 20 7 11 Date andTime 21 7 12 Cycle counter Scheduled maintenance 21 7 13 TIMER 22 WEEKLY PR...

Page 4: ...ssory protection 2 A F quick F3 power supply unit primary protection 2 5 AT delayed 5x20 mm BOARD E1SL DO NOT remove this cover Buttons SW1 SETUP RESET SW2 scrolls programming values SW3 scrolls progr...

Page 5: ...N USB storage device ERR RED error or warning BAT1 RED battery status BAT2 GREEN battery charger status SIC_OP RED safety in opening SIC_OP and SIC_CL lit simultaneously safety STOP SIC_CL RED safety...

Page 6: ...usingthescrewsprovided 7 Insertthe 2combconnectorsintotheconnectorsoftheE1SLboardasfaras the connector 8 Insert the DM board 9 on the side opposite the comb connectors as far as the connector 8 Fasten...

Page 7: ...6 7 E1SL 7 53225804 Rev B 6 8 7 10 9 12 11 Translation of the original instructions ENGLISH red black Installing the DM board 2nd MOTOR connection...

Page 8: ...he leaves can be moved safely When you exit from MANUAL mode the board will carry out a RESET OPEN mode The automation opens and remains open NIGHT TIME mode The automation closes and remains closed E...

Page 9: ...to the board 24V must not exceed 1A except SDK EVO 1 The motor M1 must be connected to connector J11 2 The encoder must be connected to connector J12 3 ADMboardmustbeinstalledonautomationsfittedwitha...

Page 10: ...relative Section PROGRAMMING For the available options see Programming configurable Inputs andthefollowingsections Theinputisactivatedaccordingtohow thecontactlogicisprogrammed NO theinputactivateswh...

Page 11: ...OP themovementstopsuntilthesafetyinopeningisdisengaged it then continues to open Low Energy the movement slows down until fully open from Board Advanced Programming Ot 1 STOP 2 Low Energy from SDK EVO...

Page 12: ...h TEST enabled DOOR NOT CLOSED 6 indicates that the automation is NOT closed DOOR OPEN 7 indicates that the automation is open DOOR MOVING 8 indicates that the automation is moving LIGHT 9 switchesont...

Page 13: ...ing modes with all the devices installed control devices safety detectors functionselectorsanddevicesconnectedtotheinputs and outputs For doors in Low Energy mode make sure that the forces gener ated...

Page 14: ...press and hold the SW1 button for approximately 5 s until LO appears on the display from SDK EVO PROGRAMMING INSTALLATION START SETUP OK 4 The display shows the phases of the SETUP L0 L2 and the statu...

Page 15: ...tton to modify it 4 PressbuttonFtoconfirmandgotothenextfunction Themodi fied value becomes effective immediately Follow the same procedure for all functions until you reach the last one St 5 WhenSt ap...

Page 16: ...65 75 cm with 1 leaf 130 150 cm with 2 leaves 3 wide opening width greater than 75 cm with 1 leaf greater than 150 cm with 2 leaves 2 rM Direction of rotation of the motor If it is modified you have t...

Page 17: ...enabled no TEST not enabled no no no no no C2 INPUT I2 configuration see options C1 4 4 4 4 4 2F INPUT I2TEST Displayed only if the input is configured as Safety C2 20 or 21 or 23 Y TEST enabled no T...

Page 18: ...no TEST not enabled no no no no no bA BATTERY KIT Operation of the emergency battery NOT in NIGHT TIME mode no not enabled 1 OPENS immediately 2 CLOSES immediately 3 with flat battery last movement OP...

Page 19: ...T NO 10 INTRUSION ACTIVE NO 11 CLOSING SAFETY NO 12 SAFETIES NO 13 AIRSLIDE SP1 NO 14 AIRSLIDE SP2 NO 15 LOCK NO o2 OUTPUT OUT2 configuration J22 see options o1 2 2 2 2 2 In Inputs status The segments...

Page 20: ...not exceed 67 N Alternatively for doors that open onto heavy traffic areas or when any contact with the user is unacceptable because many of the users are elderly sick disabled or children additional...

Page 21: ...ISABLED 7 12 CYCLE COUNTER SCHEDULED MAINTENANCE SDK EVO allows the ABSOLUTE and RELATIVE cycle counters to be managed and to program the maintenance request based on the number of cycles carried out...

Page 22: ...s DONOTpro gram overlapping time bands Complete the weekly programming for all the required days JOLLY PROGRAMMING Program the JOLLY time bands The JOLLY programming must be applied to the dates speci...

Page 23: ...d in MANUAL mode If there is a power failure the position of the XB LOCK remains un changed When the automation is operating on battery the motor block is only active in NIGHT mode operation can only...

Page 24: ...NCTION SURVEILLANCE KIT BATT FUNCTION MOTOR BLOCK FUNCTION DISABLED EL 0 not active NIGHT EL 6 with the automation in NIGHT mode locks the closed leaves and the open leaves with the Pharmacy Open comm...

Page 25: ...or safety Use the XV1 or XDT1 exit and entry detector in compliance with EN 16005 2012 and DIN18650 The defaultprogrammingoftheE1SL corresponds to the typical example configuration shown in the figure...

Page 26: ...th persons is not allowed TheXDT1dualtechnologydetectorsallowradardetectiontobeused foropeningandinfrareddetectiontobeusedforsafety Install2entry and 2 exit radar detectors to cover large accesses in...

Page 27: ...ns of safety detectors TheXBFAONinfrareddetectorsallowsafetyinopeningincompliance with EN 16005 2012 and DIN18650 The defaultprogrammingoftheE1SL corresponds to the typical example configuration shown...

Page 28: ...lsareconsideredasauxiliarydevices complementarytosafety Button photocells are monitored by the electronic board which controls correct operation at each movement 1 Connect the photocells CABLE colour...

Page 29: ...IRSLIDE an automation with an AIRSLIDE device INSTALLING INTERCOM 1 Connect all the boards together using 3 wires in a cascade con figuration in any order to the dedicated connectors 2 Connect the SDK...

Page 30: ...accesses are closed again Use one direction radar detectors see relative section INTERLOCK is not available on E1RD boards INTERLOCK can be with or without memory INTERLOCKWITH NO MEMORY OPEN detecto...

Page 31: ...2 02 DOOR NOT CLOSED 6 with contact logic NORMALLY OPENED 01 CLOSING SAFETY 11 with contact logic NORMALLY OPENED 4 OnAIRSLIDE assignthepre setIDusingtheDIPswitchesonboard E1AS follow the instructions...

Page 32: ...ed IDs the EMERG inputs only activate the board that is connected E g EMERG OPEN connected to ID2 for the emergency opening of ID2 only MODFUN input The MODFUN is set on the MASTER ID1 TIMER input The...

Page 33: ...lit To display the error code press the and buttons simultane ously The errors are described in the Diagnostics Section Press F to return to the menu When finished remove the USB storage device Downlo...

Page 34: ...r USB GREEN USB storage device device present device not present ERR RED Error Warning in progress error no error warning warning BAT1 RED Battery status battery discharged battery charged battery in...

Page 35: ...s See ErrorsandWarnings Iftherearemultipleerrorsatthesametime theonethat has priority is displayed The display is updated after it has been resolved from SDK EVO ERRORS WARNINGS FW VERSIONS The FW ver...

Page 36: ...device 19 HIGH MECHANICAL FRICTION AUTORESET Check the leaves slide smoothly with power supply battery and motors disconnected Remove any fric tion Check the counter wheel 20 TESTonInputsconfiguredas...

Page 37: ...ery has a low charge level 71 INTERCOM The automation is in INTERCOM mode 72 INTERCOM FAULT No communication between the Master and Slave nodes 73 INTERLOCK FUNCTION ACTIVE The automation is in INTERL...

Page 38: ...Incorrect Opening Position RESET the board If the error persists replace the board 218 OBSTACLE DM Check for obstacles 219 BOARD ID ERROR Replace the board 220 BOARD POWER SUPPLY FAULT DM RESET the bo...

Page 39: ...activated Check the motor connection Make sure that the motor block is not blocked Check presence of motor power supply voltage The door DOES NOT OPEN The safeties in opening are busy The emergencies...

Page 40: ...ive operating mode remains on If the LEDs are both lit at the same time it indicates that the automation is in an operating mode that is NOT available on the KS EVO OPERATION To select the operating m...

Page 41: ...e 27 Motor rotation error 29 DM board fault 30 Serious error 32 Motor time out 38 Configuration error 39 SETUP data missing or corrupted 99 Total deletion of board data LK EVO LOCK DEVICE The lock dev...

Page 42: ...ve and Common contacts TX Data transmission RX Data reception V 24V accessories power supply usea4twistedpairU UTPAWG24cablewithamaximumlength of 50 m 5 Assemble the parts and fix it in place with the...

Page 43: ...the cable knockout 2 3 Mark the points 3 on the wall and fasten the support using suitable screws F Before connecting the device disconnect the mains power supply and the emergency battery of the auto...

Page 44: ...pears After a series of screens it reverts to the HOME PAGE PASSWORD PSW When the PASSWORD screen appears a 4 digit password must be entered There are 2 passwords USER PSW and TECHNICIAN PSW By defaul...

Page 45: ...ctions using the buttons LANGUAGE PROGRAMMING TECHNICIAN PSW required ERRORS WARNINGS INTERCOM only available on the MASTER board specified in PROGRAMMING INTERCOM CYCLES COUNT DATE TIME TIMER PASSWOR...

Page 46: ...O FRAN AIS ESPANOL SVENSKA PROGRAMMING LANGUAGE ERRORS WARNINGS CYCLES COUNT DATE TIME TIMER PASSWORD INFO 1 LANGUAGE 2 PROGRAMMING 3 ERRORS 4 WARNINGS 5 CYCLES COUNT MAINTENANCE CYCLES NUMBER CYCLES...

Page 47: ...NT MOTION INPUTS OUTPUTS TIMING ENERGY SAVING BATTERY KIT KIT LOCK 2 PROGRAMMING INSTALLATION MISCELLANEOUS OUTPUTS O1 O2 MOTOR ROT INPUTS I1 I4 INPUTS STATUS INPUTS S1 S2 DOOR STATUS OTHER BOARD DATA...

Page 48: ...led relative Section ENABLED DISABLED AIRSLIDE Allows AIRSLIDE to be enabled relative Section ENABLED DISABLED NODES ENTRY This is available if the SDK EVO is connected to the board ID 1 and allows al...

Page 49: ...SF1400 and GBF1500 Allows the elastic anti panic kit to be enabled disabled ENABLED DISABLED MENU 3 ERRORS The display shows current errors Diagnostics Section MENU 4 INDICATIONS The display shows cu...

Page 50: ...ws theTECHNICIAN PSW to be modified Enter the currentTECHNICIAN PSW then the new NEW PSW and press OK Re enter theNEWPSWandconfirmwithOK IfthePSWisnotrepeatedcorrectly theSDKEVO continues to request c...

Page 51: ...E1SL 51 53225804 Rev B...

Page 52: ...FAAC S p A Soc Unipersonale Via Calari 10 40069 Zola Predosa BOLOGNA ITALY Tel 39 051 61724 Fax 39 051 09 57 820 www faac it www faacgroup com E1SL 52 53225804 Rev B...

Reviews: