The configurable outputs allow warnings to be generated from the
board under certain conditions. These outputs have an assigned func-
tion (
Configurable outputs), which are modifiable in programming.
Carry out the programming, then make the connections.
PROGRAMMING
For the available options, see
Programming configurable Outputs
and the following sections. The output is activated according to how
the contact logic is programmed: NO = the contact closes when the
output is active, NC = the contact opens when the output is active.
-
from Board
Advanced Programming:
o1
,
o2
. The contact logic is assigned
by Default.
or
-
from SDK EVO
:
/
PROGRAMMING
/
INPUTS/OUTPUTS
…
…
OUTPUTS O1/O2
(select the output)
…
FUNCTION
(select no…15)
…
NO/NC
(the output contact logic has to be programmed)
GONG (1)
indicates that at least one input configured as safety in
closing/Stop is active. Indicated at 1 s intervals.
ERROR (2)
indicates an error, or INTRUSION in NIGHT-TIME mode, or
a LOCK fault in NIGHT-TIME mode event is active.
BATTERY (3)
indicates that the automation is operating on the battery,
as there is no mains power.
EMERGENCY ACTIVE (4)
indicates that at least one input configured as
emergency is active.
SAFETIES TEST (5)
carries out a test on the devices connected to the
inputs configured as Safeties and with TEST enabled.
DOOR NOT CLOSED (6)
indicates that the automation is NOT closed.
DOOR OPEN (7)
indicates that the automation is open.
DOOR MOVING (8)
indicates that the automation is moving.
LIGHT (9)
switches on the courtesy light when the automation starts
to open. The output remains active for 60 s (time can be modified
via the SDK EVO up to 240 s).
INTRUSION ACTIVE (10)
when the automation is closed, indicates an
unexpected opening (the encoder detects a movement of more
than 1 cm).
CLOSING SAFETY (11)
indicates that at least one Safety in Closing is
active.
SAFETIES (12)
indicates that at least one Safety in Closing or Opening
is active.
AIRSLIDE SP1 (13)
indicates that the air is activated at speed SP1 when
the AIRSLIDE is in manual.
AIRSLIDE SP2 (14)
indicates that the air is activated at speed SP2 when
the AIRSLIDE is in manual.
LOCK (15)
indicates that the Motor block is on.
CONNECTIONS
Do not exceed the maximum load indicated. If you use output O1, connect the
device to 01 and V.
O1, O2 (TERMINAL BOARD J22)
V G 01 02 02
O2
Relay contact output OUT2 Max load 2A +24 V
"
O2
O1
Open Collector output OUT1 Max load 100 mA
G
GND
Accessories power supply negative and Common contacts
V
+24 V
"
accessories power supply
6. CONFIGURABLE OUTPUTS
4
Configurable outputs
Exit
(terminal board)
Default programming
Board function and
(default):
O1
(J22)
AUTOMATION NOT CLOSED (NO)
o1
(
6
)
O2
BOARD ERROR/FAULT (NO)
o2
(
2
)
5
Programming Configurable Outputs
SDK EVO function
Board value and (default):
Output NOT enabled
no
GONG
1
(NO)
ERROR
2
(NO)
BATTERY
3
(NO)
EMERGENCY ACTIVE
4
(NO)
SECURITIES TEST
5
(NC)
DOOR NOT CLOSED
6
(NO)
DOOR OPEN
7
(NO)
DOOR MOVING
8
(NO)
LIGHT
9
(NO)
INTRUSION ACTIVE
10
(NO)
CLOSING SAFETY DEVICE
11
(NO)
SAFETIES
12
(NO)
AIRSLIDE SP1
13
(NO)
AIRSLIDE SP2
14
(NO)
LOCK
15
(NO)