4.3 Terminal-boards and connectors

4.2 E064 board components 

 4 E064 CONTROL BOARD

4.1 Technical specifications

Fig. 1

4.4 DS1 Programming dip-switches

4.5 Operating logics

Logic A (automatic)

Logic E (semi-automatic)

(1)  Prevents closing if pulse is maintained.

(2)  Prevents closing and/or opening if pulse is 

maintained.

Description

Connected device

OPEN A

Command device with N.O. contact

(see chap. OPERATING LOGICS)

STOP

Device with N.C. contact which stops the 

automated system

Negative for OPEN A and STOP devices

FSW

Closing safety device with N.C. contact (see 

chap. OPERATING LOGICS)

LAMP

OPEN COLLECTOR 24 Vdc 100 mA. output for 

flashing lamp

-TX FSW

Negative for powering safety accessories (FAIL 

SAFE function)

Negative for powering accessories 

+24 Vdc for powering accessories 

No. Function

OFF

ON

1 Fail Safe

Enabled

Not enabled

2 Anti-crushing sensitivity

Low

High

3 Not used

/

/

4 Carriage speed

High

Low

Status

Open (pulse)

Stop

Fsw

CLOSED

Opens and closes 

after pause time

No effect (2)

No effect 

OPENING

No effect 

Locks  (2)

No effect  (1)

OPEN IN 

PAUSE

Resumes counting of 

pause time (1)

Locks  (1)

Resumes counting of 

pause time (1)

CLOSING

Reverses motion

Locks (2)

Reverses motion

LOCKED

Closes

No effect  (2)

No effect  (1)

Status

Open (pulse)

Stop

Fsw

CLOSED

Opens

No effect (2)

No effect 

OPENING

Locks

Locks (2)

No effect  (1)

OPEN

Closes

No effect  (2)

No effect  (1)

CLOSING

Reverses motion

Locks (2)

Reverses motion

LOCKED

Closes

No effect  (2)

No effect  (1)

Supply voltage (V ~ / Hz.)

230 / 50

Power supply to accessories (Vdc)

24

Accessories max. load (mA.)

200

Operating ambient temperature (°C)

-20 / +55

Quick-fit connector

for receiver boards XF433 / 

XF868 and battery module

Operating logics

Automatic / Semiautomatic 

Terminal-board connections

Open/Stop/Safety devices/Fail-

safe/Flashing lamp 24 Vdc

Courtesy light timer (min.)

2

J1

Low voltage inputs/accessories terminal board

J2

Quick-fit connector for receivers XF433 or XF868

J3

230V power supply input terminal board

J4

Connector for transformer primary winding

J5

Courtesy light terminal-board

J7

Connector for transformer secondary winding

J8

Motor output connector

J12

Battery module connector 

OPEN A

Radio signal programming push-button

OPEN B

Radio signal programming push-button

OPEN

OPEN push-button

SETUP

SET-UP push-button

DS1

Programming dip-switch

LD1

Signalling LED: OPEN input

LD2

Signalling LED: STOP input

LD3

Signalling LED: FSW input

LD4

Signalling LED: SET UP cycle

LD5

LED signalling memory-storage: radio channel OPEN A

LD6

LED signalling memory-storage: radio channel OPEN B

Fail Safe

If activated, it enables the photocell operating test before every 

movement.

Operating logics

For doors with an irregular movement, it reduces the sensitivity of 

the anti-crushing device to prevent unwanted action by it.

Summary of Contents for D064

Page 1: ...D064...

Page 2: ...ust not encroach public areas dedicated to pedestrian or vehicular transport Check the efficiency of the door bearings and joints Make sure that the door is friction free If necessary clean and lubric...

Page 3: ...contact with moving parts Install the fixed control points at a minimum height of 150 cm clear of the door movement area but in a position enabling visual control of that area Cable 2 x 0 5 mm2 TX ph...

Page 4: ...ONLY FOR EXTERNAL MECHANICAL RELEASE 4 5 1 3 2...

Page 5: ...max 20 cm max 40 cm 15 20 OPTIONAL ONLY FOR EXTERNAL MECHANICAL RELEASE 6 7 7 8 9 J K L...

Page 6: ...top Fsw CLOSED Opens No effect 2 No effect OPENING Locks Locks 2 No effect 1 OPEN Closes No effect 2 No effect 1 CLOSING Reverses motion Locks 2 Reverses motion LOCKED Closes No effect 2 No effect 1 S...

Page 7: ...input is not used jumper connect the input to the terminal If the photocells are not used connect the FSW input to terminal TX FSW Input status LEDS The automated system stopped and at rest is indica...

Page 8: ...unit independently determines the movement parameters If the procedure is not correctly concluded e g due to excessive friction during door movement the unit signals a fault status the SET UP LED flas...

Page 9: ...y During these 5 seconds in order to lighten the load on the release system you can send OPEN pulses within a time interval of 2 seconds from each other in order to reverse the carriage One pulse corr...

Page 10: ...within which time the code of another radio control must be transmitted 6 The LED lights up on steady beam for 2 seconds indicating memory storage executed and then resumes flashing for 5 sec during...

Page 11: ...perform any movement STOP command enabled The automated system opens the door but does not close it FSW safety devices engaged The Fail Safe function is enabled but the NC contact of the devices conne...

Page 12: ...gging and shearing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices m...

Reviews: