These instructions apply to model
FAAC D064
.
The D064 automated systems make it possible to automate
balanced sectional doors of single garages for residential
use.
They consist of an electro-mechanical operator, electronic
control unit and courtesy light built into a single unit. This unit is
fitted to the ceiling and opens the door by means of a transmission
chain or belt.
The system is non-reversing and, therefore, the door locks
mechanically when the motor is not operating and, consequently,
no lock is necessary; two manual releases, one on the inside
and one on the outside (optional) make it possible to move the
door in case of a power cut or fault.
The operator is supplied with an electronic device that detects
the presence of an obstacle that would hinder door movement
- the device prevents crushing or lifting.
This instruction refers to the operator with chain drive, but the
same procedures, regulations and application limits apply also
to the belt driven operator.
The D064 automated systems were designed and built for
indoor use and to control vehicle access. Do not use them for
any other purpose.
AUTOMATED SYSTEM D064
1 PRELIMINARY CHECKS
- The structure of the door must be suitable for fitting automation.
In particular, check that the door dimensions conform to
those indicated in the technical specifications, and that it is
sufficiently sturdy.
- Check if the door conforms to standards EN12604 and
EN12605.
- As it moves, the door must not encroach public areas
dedicated to pedestrian or vehicular transport.
- Check the efficiency of the door bearings and joints.
- Make sure that the door is friction-free. If necessary clean
and lubricate the guides with silicone based products, but do
not use grease, and, in any event, follow the manufacturer’s
instructions.
- Check correct balance and if the opening mechanical stops
have been installed.
- Remove the door’s existing closing mechanism to ensure the
door is closed by the automated system.
- Make sure there is a clearance of at least 35 mm between the
ceiling and the highest sliding point of the door .
- Check if the upper guide roller of the sectional door is in the
horizontal part of the guide while the door is closed.
2 TECHNICAL SPECIFICATIONS
Model
D064
Power supply (V ~ / 50 Hz.)
230
Electric motor (Vdc)
24
Maximum absorbed power (W)
220
Thrust force (N)
550
Type of use
Residential
Maximum dimensions from ceiling (mm)
35
Courtesy light (V ~/W)
230 / 40 max.
Courtesy light timer (sec)
120
Standard speed with no-load carriage (m/min)
6,6
Slow speed with no-load carriage (m/min)
3,8
Carriage deceleration speed (m/min)
1,3
Travel length at deceleration
varies according to set-up
Intrinsic safety device
Category 2
Maximum sectional door width (mm)
5000
Maximum sectional door height (mm)
2600
Sliding guide useful travel (mm)
2600
Protection class
for indoor use only (IP20)
Operating ambient temperature (°C)
-20 / +55
Ceiling lamp
Rear door
Courtesy light
Plastic housing for D064 operator
Rear fitting
Sliding guide
Drive carriage
Release knob
Door fitting bracket
Transmission unit
Front fitting and chain tensioner
Front fitting bracket