Prepare the electric system in keeping with the instructions in 

the chapter entitled “Warnings for the installer”.

When you have finished installing, check if any external pipes 

or cables can come into contact with moving parts. 

Install the fixed control points at a minimum height of 150 cm, 

clear of the door movement area, but in a position enabling 

visual control of that area.

  Cable 2 x 0.5 mm

2

 (TX photocell)

 

Cable 4 x 0.5 mm

2

 (RX photocell)

  Power pipe (230V)

  Low voltage pipe

 

Cable 2 x 1.5 mm

2

 (power)

  3 ANCILLARY ELECTRICAL EQUIPMENT

3200 (for disassembled rail) 

2600 (for disassembled rail) 

*     For rail assembling, plase refere to 

dedicate instruction

*

*

Summary of Contents for D064

Page 1: ...D064...

Page 2: ...ust not encroach public areas dedicated to pedestrian or vehicular transport Check the efficiency of the door bearings and joints Make sure that the door is friction free If necessary clean and lubric...

Page 3: ...contact with moving parts Install the fixed control points at a minimum height of 150 cm clear of the door movement area but in a position enabling visual control of that area Cable 2 x 0 5 mm2 TX ph...

Page 4: ...ONLY FOR EXTERNAL MECHANICAL RELEASE 4 5 1 3 2...

Page 5: ...max 20 cm max 40 cm 15 20 OPTIONAL ONLY FOR EXTERNAL MECHANICAL RELEASE 6 7 7 8 9 J K L...

Page 6: ...top Fsw CLOSED Opens No effect 2 No effect OPENING Locks Locks 2 No effect 1 OPEN Closes No effect 2 No effect 1 CLOSING Reverses motion Locks 2 Reverses motion LOCKED Closes No effect 2 No effect 1 S...

Page 7: ...input is not used jumper connect the input to the terminal If the photocells are not used connect the FSW input to terminal TX FSW Input status LEDS The automated system stopped and at rest is indica...

Page 8: ...unit independently determines the movement parameters If the procedure is not correctly concluded e g due to excessive friction during door movement the unit signals a fault status the SET UP LED flas...

Page 9: ...y During these 5 seconds in order to lighten the load on the release system you can send OPEN pulses within a time interval of 2 seconds from each other in order to reverse the carriage One pulse corr...

Page 10: ...within which time the code of another radio control must be transmitted 6 The LED lights up on steady beam for 2 seconds indicating memory storage executed and then resumes flashing for 5 sec during...

Page 11: ...perform any movement STOP command enabled The automated system opens the door but does not close it FSW safety devices engaged The Fail Safe function is enabled but the NC contact of the devices conne...

Page 12: ...gging and shearing 16 Use of at least one indicator light e g FAACLIGHT is recommended for every system as well as a warning sign adequately secured to the frame structure in addition to the devices m...