13
ENGLISH
o LED 5
OPEN
The door opens and remains open.
o LED 4
AUTOMATIC
The door opens when internal or
external commands are active and
re-closes after the pause time.
o LED 3
AUTOMATIC (SPARE)
o LED 2
ONE-WAY
Entry (or exit) inhibited; only one
direction of exit (or entry); opening
when internal (or external) command
is active; closing after pause time.
The external (or internal) control
devices are inactive.
o LED 1
NIGHT
The door is locked shut by the electric
lock.
The external command is inactive.
The door can be opened solely by
activating the internal command or
EMERGENCY OPENING input. The
door closes after the night pause
time.
Vc
P
Tp
Vo
1
0
2
Fig. 20
POSITION “1”: AUTOMATIC
When an internal/external command is given, the
door opens and then re-closes after the pause
time.
POSITION “0”: MANUAL/NIGHT
The position “0” can be used to select two different
operating functions according to the programming
carried out on the 959 B-E programming unit (see
section 5.3).
The two functions are:
MANUAL:
The door can be opened manually. The
return spring pulls the door closed again.
NIGHT:
The external command is inactive. The door
can be opened solely by activating the internal
command (fig. 17) or EMERGENCY OPENING (fig.
19/a) input.
POSITION “2”: OPEN
When this function is selected, the door opens and
remains open. The door can be closed only by
activating the EMERGENCY CLOSURE input (fig.19/
a).
LEDS DI SEGNALAZIONE
FUNZIONI
REGOLABILI
PULSANTI DI COMANDO
FUNZIONI
OPERATIVE
ERROR
Tpn
Tp
P
Vc
Vo
RESET
6
5
4
3
2
1
OPERATING
FUNCTIONS
STATUS LEDS
PUSHBUTTON
CONTROLS
ADJUSTABLE
FUNCTIONS
8.2. LEVEL II - ADJUSTABLE FUNCTIONS
Important:
Level II is active only if the CODIS is used permanently
(function 7 of Level III activated). The CODIS programming unit
has one adjusting level.
Six parameters can be set. They are displayed on the right-
hand side of the CODIS front panel, with the relevant LEDs:
RESET
LED 6 o
RESET
: repeat initialisation process
(see paragraph 4.1).
LED 5 o
OPENING SPEED
: adjust to 30
⇒
100%
of initialisation value.
The standard setting is 100%.
LED 4 o
CLOSING SPEED
: adjust to 30
⇒
66% of initialisation value.
The standard setting is 66%.
LED 3 o
OPENING EXCURSION
: adjust
maximum opening by 60 to 100%.
The standard setting is 100%.
LED 2 o
PAUSE TIME
: adjust to 0-30 seconds.
The opening is controlled by means
Fig. 21
g
Programming unit connector
(14 pole)
7. FUNCTION SWITCH
The 959 B-E operator has a 3-position function switch (0-1-2)
mounted on one of the end covers (fig. 1 - ref. 12). This cover
can be fitted on the right or the left as required (fig. 8).
The switch electrical connection is shown in fig. 13.
The selectable operating functions are shown in fig. 20.
8. “CODIS” EXTERNAL PROGRAMMING UNIT (OPTIONAL)
The 959 B-E automation unit can also be controlled by an
external programming unit in place of the function selector
and of the 959 B-E programming unit.
The CODIS (see figure 21) has four levels of operation, where
the user can select the operating functions and set, programme
and monitor the operation of the system.
If the CODIS is used permanently, it is necessary to activate
function 7 at Level III (programming functions): see paragraph
8.3.
For the electrical connection of the CODIS, consult figure 14.
The operation of the CODIS can be inhibited in the two
following ways:
- by cutting the jumper between terminals 3 and 4 by means
of a switch (fig. 14);
- by activating function 9 at Level III; in this case it is possible to
operate the unit temporarily after having entered code
“+ + - - + +” by means of the “+” and “-” pushbuttons.
After 2 minutes the CODIS will stop again automatically.
Note:
the CODIS can also be used as a temporary programming
unit. In this case, Level II (adjustable functions) is inactive.
When the programming of the system has been completed,
the CODIS can be removed: all the programmed functions will
remain unaltered.
After having removed the CODIS, perform a RESET or switch off
the system.
8.1 LEVEL I - OPERATING FUNCTIONS
This is the level that is accessible to the user. By pressing either
the “+” or the “-” pushbutton, the user can select the operating
function.
Five operating functions are available. They are displayed on
the left-hand side of the front panel of the CODIS.
When a function has been selected, the corresponding LED
lights up on the front panel.
Press the “+” pushbutton to move the lighting of the LEDs one
position up.
Press the “-” pushbutton to move the lighting of the LEDs one
position down.
The five available functions displayed on the panel are:
o LED 6
MANUAL
The door is released and can be
operated manually.
The control devices are inactive.