14
ENGLISH
of the activation of the internal/
external control devices.
The standard setting is 2 seconds.
LED 1 o
NIGHT PAUSE TIME:
adjust to 0-30
seconds. The opening is controlled
by means of the activation of the
KEY/EMERGENCY OPENING
commands.
The standard setting is 7 seconds.
8.2.1. ADJUSTMENT OF PARAMETERS
To access Level II (adjustable functions), proceed as follows:
1)
Select the parameter to be adjusted by causing the relevant
LED to light up. Press the “+” pushbutton to move the
lighting of the LEDs one position up. Press the “-” pushbutton
to move the lighting of the LEDs one position down.
2)
Press the “+” and “-” pushbuttons
simultaneously
.
The LED relevant to the selected parameter will start
flashing in order to give information about the stored
value: if the flashing rate is high, a high door speed or a
short pause time has been stored; if the flashing rate is low,
a low door speed or a long pause time has been stored.
3)
Press the “+” or “-” pushbutton repeatedly, in order to
increase or decrease the flashing frequency of the LED,
that is to say, to change the value of the selected
parameter. When the “+” pushbutton is pressed, the door
speed, opening excursion and pause time are increased.
When the “-” pushbutton is pressed, the door speed,
opening excursion and pause time are decreased.
4)
Return to Level I (operating functions) by pressing the “+”
and “-” pushbuttons
simultaneously
.
Notes:
- The CODIS automatically returns to Level I after 2
minutes of inactivity.
- To prevent the settings from returning to standard
values after a RESET or a voltage drop, “protect” the
programmed values by activating function 18 at
Level III (see paragraph 8.3).
8.3. LEVEL: III - PROGRAMMING FUNCTIONS
The CODIS has a programming level where certain functions
can be selected.
These functions are required for several special applications.
Note:
a voltage drop or a RESET command will not cancel the
programming on Level III.
Standard programming can be restored by means of function
15 (see Table 7).
To access Level III, proceed as follows:
1)
Select the
NIGHT
operating function by causing LED 1 to
light up. Press the “+” pushbutton to move the lighting of
the LEDs one position up. Press the “-” pushbutton to move
the lighting of the LEDs one position down.
2)
Press the “+” and “-” pushbuttons
simultaneously
for about
2 seconds
, until the red
ERROR
LED lights up.
3)
Enter the access code by pressing the “+” and “-”
pushbuttons in the following sequence: “
+ + + - - + + +
”.
Note:
after the lighting up of the red ERROR LED, if the code is
not entered
within 10 seconds
the CODIS will automatically
return to Level I.
4)
.Select the function to be programmed by pressing the “+”
or “-” pushbutton so as to obtain the combination of lit
LEDs indicated in Table 7.
5)
Press the “+” and “-” pushbuttons
simultaneously
to activate
or deactivate the function, and check the status of LED 6,
according to the indications of Table 7.
Note
: the standard programming is the one with LED 6 unlit
(OFF).
6)
To return to Level I (operating functions),
repeatedly
press
the “-” pushbutton until all the six LEDs are off, then press
the “+” and “-” pushbuttons
simultaneously
.
Note
: the CODIS will automatically return to Level I after 2
minutes of inactivity.
FUNCT.NO.
LEDS
FUNCTIONS
LED 6
1
2
3
4
5
0
OFF OFF OFF OFF OFF
Output Level III
OFF
1
ON
OFF OFF OFF OFF
One-way with lock active
OFF
One-way with lock inactive
ON
2
OFF
ON OFF OFF OFF
NIGHT function (terminal 3-959MP)
OFF
ONE-WAY function (terminal
ON
3-959MP)
5
ON
OFF ON OFF OFF
Emergency closing (terminal
OFF
11-959MP)
Emergency opening (terminal
ON
11-959MP)
6
OFF
ON ON OFF OFF
Emergency command - N.C.
OFF
contact (terminal 11-959MP)
Emergency command - N.O.
ON
contact (terminal 11-959MP)
7
ON
ON ON OFF OFF
CODIS - temporary connection
OFF
CODIS - permanent installation
ON
8
OFF OFF OFF ON OFF
15 kg static force
OFF
9 kg static force
ON
9
ON
OFF OFF ON OFF
CODIS inhibited inactive
OFF
CODIS inhibited active
ON
10
OFF
ON OFF ON OFF
Standard opening pause time
OFF
Immediate closing
ON
15
ON
ON ON ON OFF
Restore STANDARD settings
OFF
Retain programmed settings
ON
17
ON
OFF OFF OFF ON
TEST programme inactive
OFF
TEST programme active
ON
18
OFF
ON OFF OFF ON
Level II RESET active
OFF
Level II RESET inactive
ON
19
ON
ON OFF OFF ON
STANDARD internal command
OFF
(terminal 9-959MP)
STEP-BY-STEP internal command
ON
(terminal 9-959MP)
Table 7: programming functions
Tpn
8.3.1. AVAILABLE FUNCTIONS
function 1
One-way with lock activated: in the ONE-WAY operating
function, the closed door is locked by the electric lock.
One-way with lock deactivated: in the ONE-WAY operating
function, the closed door is not locked by the electric lock.
function 2
NIGHT function: the activation of the input between terminals
2 and 3 (959MP) selects the NIGHT operating function,
with
priority
over the function selected on the CODIS.
ONE-WAY function: the activation of the input between
terminals 2 and 3 (959MP) selects the ONE-WAY operating
function,
with priority
over the function selected on the CODIS.
The control panel will show which function has been selected,
by means of the lighting up of LED 1 or 2.
When the input is deactivated, the operating function
previously selected on the CODIS returns automatically.
function 5
Emergency closing: the activation of the input between
terminals 11 and 15 (959MP) controls the closing of the door no
matter which operating function has been selected.
Emergency opening: the activation of the input between
terminals 11 and 15 (959MP) controls the opening of the door
no matter which operating function has been selected.