IMPORTANT NOTICE FOR THE INSTALLER

GENERAL SAFETY REGULATIONS

1) WARNING!

 

FAAC  strongly  recommends  to  follow  these  instructions  literally  for  the  safety  of  persons.  Improper

installation or misuse of the product will cause very serious damages to persons.

2) Packaging material (plastic, polystyrene etc.) is a potential hazard and must be kept out of reach of children.

3) Read the instructions carefully before installing the product.

4) Keep these instructions for future reference.

5) This product has been designed and manufactured only for the use stated in this manual. Any other use not expressly

set forth will affect the reliability of the product and/or could be source of hazard.

6) FAAC S.p.A. cannot be held responsible for any damage caused by improper use or different from the use for which

the automation system is destined to.

7) Do not use this device in areas subject to explosion: the presence of flammable gas or fumes is a serious hazard.

8) Mechanical constructive elements must comply with CEN pr EN 12650-1 and CEN pr EN 12650-2 standards.

Countries outside the EC shall follow the regulations above besides their national normative references in order to offer
the utmost safety.

9) FAAC cannot be held responsible for failure to observe technical standards in the construction of gates and doors,

or for any deformation of the gates which may occur during use.

10) Before carrying out any operations, turn off the system’s main switch.

11) An omnipower switch shall be provided for the installation with an opening distance of the contacts of 3 mm or more.

Alternatively, use a 6A thermomagnetic breaker with multi-pole switching.

12) Ensure that there is a differential switch up-line of the electrical system, with a trip threshold of 0.03A.

13) Check that the earthing plant is in perfect condition and connect it to the metallic parts. Also earth the yellow/green

wire of the operator.

14) The automation is fitted with an anti-crush safety system that is a torque control device. In any case, further safety

devices shall be installed.

15) The safety devices (e.g. photocells, safety edges, etc.) protect areas wherethere is a mechanical movement hazard,

e.g. crushing, entrapment and cutting.

16) Each installation must be fitted with at least one warning plate suitably fixed to the gate, besides the safety devices

as per point 15. above.

17) FAAC cannot be held responsible regarding safety and correct functioning of the automation in the event that parts

other than FAAC original parts are used.

18) Use only FAAC original spare parts for maintenance operations.

19) Do not carry out any modifications to automation components.

20) The installer must supply all information regarding manual operation of the system in the event of an emergency and

provide the end-user with the leaflet attached to the product.

21) Keep out of persons when the product is in operation.

22) Keep out of reach of children the remote radio controls and any control devices. The automation could be operated

unintentionally.

23) The end-user must avoid any attempt to repair or adjust the automation personally. These operations must be carried

out exclusively by qualified personnel.

24) What is not explicitly stated in these instructions is not permitted.

Summary of Contents for 959 B-E

Page 1: ...tfreundlich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 per la natura carta riciclata 100 para la naturaleza 100 papel reciclado C ERME T A Z I E N D A C E R TIF I C A...

Page 2: ...bsequent amendments 91 368 EEC 93 44 EEC and 93 68 EEC complieswiththeessentialsafetyrequirementsinthefollowingEECDirectives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amen...

Page 3: ...with an opening distance of the contacts of 3 mm or more Alternatively use a 6A thermomagnetic breaker with multi pole switching 12 Ensure that there is a differential switch up line of the electrical...

Page 4: ...3 ITALIANO Fig 2a Fig 3 Fig 2b Fig 4 Fig 8 2x0 5 mm2 2x0 5 mm 2 2x0 5 mm 2 3x1 5 mm 2 230 V 2 x 0 5 mm 2 6 5 4 3 7 1 8 2 2 2x0 5 mm 2 schermato screened blind abgeschimt apantallado...

Page 5: ...4 ITALIANO Fig 5 90 90 2 1 2 1 3 7 6 5 4 2 1 a b 45 45 1 3 2 1 4 4 1 a b Fig 6...

Page 6: ...eje est ndar por una de lasopcionales prolongaci n de 20 mm prolongaci n de 50 mm En tal caso sumar a las cotas interesadas la altura correspondiente 20 50 mm Quote in mm Dimensions in mm Cotes en mm...

Page 7: ...e der beiden optionalen Verl ngerungen ersetzen Wellenverl ngerung 20 mm Wellenverl ngerung 50 mm In diesem Fall ebenfalls die betreffenden H henma evergr ern 20bzw 50mm Cota con prolongaci n del eje...

Page 8: ...prolongaci n de 20 mm prolongaci n de 50 mm En tal caso sumar a las cotas interesadas la altura correspondiente 20 50 mm 0 160 Quota con prolunga albero standard Nel caso sia necessario aumentare la d...

Page 9: ...nal 24 Vdc electric lock power supply N O N C 24 Vdc accessories power supply Terminalstripinputs Functionswitch CODIS optional Internal external emergency STOP safety device CLOSURE safety device 1 1...

Page 10: ...d use the higher extensions available as accessories see Table A B 4 Mount plate 5 of arm 2 on the door or the lintel using the two M6 screws and the washers provided fig 5 The installation distances...

Page 11: ...s of the settings Turn the trimmers anticlockwise to reduce the values of the settings 5 3 PROGRAMMING THE MICROSWITCHES fig 10 The programming unit has a series of microswitches which allow the funct...

Page 12: ...12 STOP safety control fig 19 a any device safety sensor photocell etc which by opening a contact has a safety effect on the operating cycle In particular this safety device interrupts the opening cl...

Page 13: ...LOCK N O EL LOCK COM L screened cable 2 x 0 5 mm2 50 m max 2 NIGHT ONE WAY CODIS L L 1 2 3 2 1 4 3 0 Vdc 1 1 230 V 6 10 50 60 Hz N F N O C INTERNAL SENSOR N F N O C EXTERNAL CONNECTOR BROWN WHITE GREE...

Page 14: ...mum opening by 60 to 100 The standard setting is 100 LED 2 o PAUSE TIME adjust to 0 30 seconds Theopeningiscontrolledbymeans Fig 21 g Programming unit connector 14 pole 7 FUNCTION SWITCH The 959 B E o...

Page 15: ...of lit LEDs indicated in Table 7 5 Pressthe and pushbuttonssimultaneouslytoactivate or deactivate the function and check the status of LED 6 according to the indications of Table 7 Note the standard...

Page 16: ...onsecutive operating cycles The control devices in any case take priority over the operation of the system The programme can be cancelled by performing a RESET function 18 Level II RESET active inacti...

Page 17: ...or allow children or adults to stand within range of the door especially during operation and do not leave objects near it Do not allow children to play with the door Do not deliberately obstruct move...

Page 18: ...ner al d a la presente publicaci n todas las modificaciones que considere oportunas para el perfeccionamiento t cnico o para cualquier otro tipo de exigencia de car cter constructivo o comercial FAAC...

Reviews: