background image

6

FC2

FC1

DIR2

DIR1

5.6 ADJUSTMENT OF LIMIT-SWITCH UNIT

The procedure for adjusting the closing and opening limit-

switch is as follows:

Completely close the industrial sectional door. 

Using trimmer 1, with the arrow facing down (closing), turn

clockwise to + or anti-clockwise to - until 

the closing limit-switch is activated.

Then set the industrial sectional door in opening position.

Using trimmer 1, with the arrow facing up (opening), turn

clockwise to + or anti-clockwise to - until 

the opening limit-switch is activated (see fig. 11).

Note for fine adjustment: the “+” symbol indicates backing 

away of the activator from the microswitch and therefore 

a longer stroke; the “-” symbol, on the contrary, indicates its 

approach and consequently a shorter stroke.

Final check of the open and closed positions.

Manually move the door in open and close position.

Ensure that the operator actually reaches the desired positions 

when opening and closing. If this does not occur, correct the 

limit-switch positions using trimmer  1. 

If used with 578D equipment, you can correct the closing stop 

point also by varying the post-end of travel deceleration.

Fig. 11

  

Limit-switch trimmer 

up and down adjusting

  

microswitch limit-switch up and down

5.7 IDENTIFYING ROTATION DIRECTION (operator with 844T 

equipment)

Figure 12 shows rotation directions Dir1 and Dir2. Motion in Dir1 direction is 

stopped by FC1 and motion in Dir2 direction by FC2. Consequently, if, for 

example, Dir2 is the rotation direction causing the door to close, FC2 deter

-

mines the stop closing point and FC1 determines the opening stop point.

 The OPEN command is normally associated with Dir1 motion - consult the 

equipment instructions if the rotation directions have to be reversed. 

The stop spring of the ring-nuts activating the limit-switches, is kept lifted up 

by the square - the latter must not be removed until the door stop points 

are adjusted.

Fig. 12

Summary of Contents for 541 3ph

Page 1: ...541 3ph 541 3ph...

Page 2: ...r any deformation that may occur during use 10 The installation must conform to Standards EN 12453 and EN 12445 For non EU countries to obtain an adequate level of safety the Standards mentioned above...

Page 3: ...ced industrial sectional doors They consist of an electro mechanical operator with on board 541D inter connection board for remote control unit 844T Installation is possible either directly on the sha...

Page 4: ...2x0 5 Tx photocells Low voltage cabling radio receiver Low voltage cabling 6x0 5 control panel Equipment enclosure Operator Power take off Securing plate Limit switch unit Winch in models for which it...

Page 5: ...port wall or metal structure on which you have decided to secure it see figure 6 Tighten the screws without forcing them while resting the plate on the support Trace the position of the installation h...

Page 6: ...ee figure 9 so that the winch support disappears completely inside the plastic enclosure see figure 10 Check if the traction of just one of the chain sections causes the winch to engage and if the win...

Page 7: ...hat the operator actually reaches the desired positions when opening and closing If this does not occur correct the limit switch positions using trimmer 1 If used with 578D equipment you can correct t...

Page 8: ...locked operator and the relevant positions of the release ropes with red knob and locking ropes with green knob Fit the lever and make sure that it reaches the travel limits in the two directions at...

Page 9: ...cables The 541 3ph operator is supplied with an on board inter connection board 6 1 CONNECTIONS OF 844T ELECTRONIC EQUIPMENT Lay the raceways according to the instructions in figure 4 Make the connec...

Page 10: ...the equipment activates the electric motor which drives the door to opening position to permit access In dead man systems the command push button must be kept pressed for the whole duration of the ope...

Page 11: ......

Page 12: ...ldungen in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassun...

Reviews: