2. DIMENSIONS AND DESCRIPTION
1. TECHNICAL SPECIFICATIONS
Power supply (Vac 50-60Hz)
400 (+6 –10%)
Electric motor
3 - phase induction 1450rpm
Maximum absorbed power (W)
720
Absorbed current (A)
1.1
Starting capacitor (µF)
20
Winding thermal protection (°C)
140
Use frequency (S3) ROT
60%
Max number consecutive cycles
6
Power take-off
Hollow through shaft diam. 25,4mm
(1’’)
Power take-off rotation speed (rpm)
23
Rated torque of power take-off (Nm)
70
Power take-off max revs
24
Protection class
IP54
Operating ambient temperature (°C)
-20 / +55
Gearmotor max weight (Kg)
14
Type of oil
FAAC XD220
Oil quantity (l)
0,9
Note: consult Table 1 for chain transmission applications
Graph 1
Table 1
Type of
Rated
Rope shaft
Rope shaft
application
torque
speed
max revs
(Nm) (rpm)
Direct
70
23
24
Reduction ratio 1:1.5
105
17,2
18
Reduction ratio 1:2
140
11,5
12
Transmission
1:2
Transmission
1:1.5
Direct application
These instructions apply to the following models:
FAAC 541 3ph
The 541 3ph automated system is designed for automat ing balan
-
ced industrial sectional doors.
They consist of an electro-mechanical operator, with on-board
(541D) inter-connection board, for remote control unit (844T).
Installation is possible either directly on the shaft of the rope-winding
drums, or by chain transmission (optional item) with a reduction
ratio of 1:1.5 or 1:2.
The non-reversing system ensures mechanical locking of the door
when the motor is not operating and, therefore, no lock needs to
be installed; the manual release and the manual opening system
(in models for which it is supplied) make it possible to move the door
in case of a power cut or malfunction.
The 541 3ph automated systems was designed and built for indoor
and outdoor use.
Graph 1 shows with which type of application the 541 3ph can
be installed, considering the maximum force required to manually
move the door
F
, in daN (1daN = force required to lift 1,02 kg),
and the diameter of the rope-winding drum
Dt
in millimetres. For
example, if a door can be moved with a force of 108 daN and
the drum diameter is 180 mm, a 541 3ph with chain transmission of
1:1.5 must be installed.
N.B.
Force
F
can be measured with a dynamometer. It is not directly
related to the weight of the door, but to its balance.