background image

1

CE DECLARATION OF MACHINE CONFORMITY

(DIRECTIVE 2006/42/EC)

Manufacturer : 

FAAC S.p.A.

Address: 

Via Calari, 10  - 40069  Zola Predosa BOLOGNA - ITALY

Declares that:

  

 

Operator mod. 

541 3ph

 

•  is built to be incorporated into a machine or to be assembled with other machinery to create a machine under 

the provisions of Directive 2006/42/EC;

 

•  conforms to the essential safety requirements of the other following EEC directives:

 

    2006/95/EC Low Voltage directive.

 

    2004/108/EC Electromagnetic Compatibility directive

 

   and also declares  that it is prohibited to put into service the machinery until the machine in which it will  be   

 

integrated  or  of  which  it  will  become  a  component  has  been  identified  and  declared  as  conforming 

 

to the conditions of Directive 2006/42/EC.

 

                                    Bologna, 01 January 2011  

 

    The Managing Director

 

   

 

 

 

 

 

A. Marcellan

 

1)  ATTENTION! To ensure the safety of people, it is important that you read 

all the following instructions. Incorrect installation or  incorrect use of 

the product  could  cause  serious harm   to people.

  2)  Carefully read the instructions before beginning to install the product.
  3)  Do  not    leave  packing  materials  (plastic,  polystyrene,  etc.)      within  

reach of  children as  such materials  are  potential  sources  of  danger.

  4)  Store these instructions for  future reference.
  5)  This product was designed and built strictly for the use indicated in this 

documentation. Any other use, not expressly indicated here, could 

compromise the good condition/operation of the product and/or be 

a source of danger.

  6)  FAAC declines all liability caused by improper use or use other than 

that for which the automated system was intended.

  7)  Do not install the equipment in an explosive atmosphere: the presence 

of  inflammable gas or fumes is a serious danger to safety.

  8)  The mechanical parts must conform to the provisions of Standards EN 

12604 and EN 12605.

 

  For  non-EU  countries,  to  obtain  an  adequate  level  of  safety,  the 

Standards mentioned above must be observed, in addition to national 

legal regulations.

  9)  FAAC  is  not  responsible  for  failure  to  observe  Good  Technique  in 

the construction of the closing elements to be motorised, or for any 

deformation that may occur during use.

 10)  The installation must conform to Standards EN 12453 and EN 12445.

 

    For  non-EU  countries,  to  obtain  an  adequate  level  of  safety,  the 

Standards mentioned above must be observed, in addition to national 

legal regulations.

 11)  Before attempting any job on the system, cut out electrical power .
 12)  The mains power  supply of the automated system must be fitted with 

an all-pole  switch with contact opening distance of 3mm or greater. 

Use of a 6A thermal breaker with all-pole circuit break is recommended.

 13)  Make sure that a differential switch with threshold of 0.03 A is fitted 

upstream of the system.

 14)  Make sure that the earthing system is perfectly constructed, and connect 

metal parts of  the means of  the closure to it. 

 15)  The  safety  devices  (EN  12978  standard)    protect  any  danger  areas 

against 

mechanical movement Risks

, such as crushing, dragging, and 

shearing.

 16)  Use of at least one indicator-light (e.g. FAACLIGHT ) is recommended 

for every system, as well as a warning sign adequately secured to the 

frame structure, in addition to the devices mentioned at point “15”.

 17)  FAAC declines all liability as concerns safety and efficient operation of 

the automated system, if system components not produced by FAAC 

are used.

18)   For maintenance, strictly use original parts by FAAC.
 19)  Do not in any way modify the components of the automated system.
 20)  The installer shall supply all information concerning manual operation 

of the system in case of an emergency, and shall hand over to the user 

the warnings handbook supplied with the product.

 21)  Do  not  allow  children  or  adults  to  stay  near  the  product  while  it  is 

operating.

 22)  Keep remote controls or other pulse generators away from children, to 

prevent the automated system from being activated involuntarily.

 23) 

Transit under the door is permitted only when the automated system is idle.

 24)  The user must not attempt any kind of repair or direct action whatever 

and contact qualified personnel only.

 25) 

Maintenance: check at least every 6 months the efficiency of the system, 

particularly the efficiency of the safety devices (including, where foreseen, 
the operator thrust force) and of the release devices.

 

 26)  Anything not expressly specified in these instructions is not permitted.

WARNINGS FOR THE INSTALLER

GENERAL SAFETY OBLIGATIONS

Summary of Contents for 541 3ph

Page 1: ...541 3ph 541 3ph...

Page 2: ...r any deformation that may occur during use 10 The installation must conform to Standards EN 12453 and EN 12445 For non EU countries to obtain an adequate level of safety the Standards mentioned above...

Page 3: ...ced industrial sectional doors They consist of an electro mechanical operator with on board 541D inter connection board for remote control unit 844T Installation is possible either directly on the sha...

Page 4: ...2x0 5 Tx photocells Low voltage cabling radio receiver Low voltage cabling 6x0 5 control panel Equipment enclosure Operator Power take off Securing plate Limit switch unit Winch in models for which it...

Page 5: ...port wall or metal structure on which you have decided to secure it see figure 6 Tighten the screws without forcing them while resting the plate on the support Trace the position of the installation h...

Page 6: ...ee figure 9 so that the winch support disappears completely inside the plastic enclosure see figure 10 Check if the traction of just one of the chain sections causes the winch to engage and if the win...

Page 7: ...hat the operator actually reaches the desired positions when opening and closing If this does not occur correct the limit switch positions using trimmer 1 If used with 578D equipment you can correct t...

Page 8: ...locked operator and the relevant positions of the release ropes with red knob and locking ropes with green knob Fit the lever and make sure that it reaches the travel limits in the two directions at...

Page 9: ...cables The 541 3ph operator is supplied with an on board inter connection board 6 1 CONNECTIONS OF 844T ELECTRONIC EQUIPMENT Lay the raceways according to the instructions in figure 4 Make the connec...

Page 10: ...the equipment activates the electric motor which drives the door to opening position to permit access In dead man systems the command push button must be kept pressed for the whole duration of the ope...

Page 11: ......

Page 12: ...ldungen in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassun...

Reviews: