5.1 OPERATOR WORK POSITION

The  operator  -  supplied  with  a  chain-operated  manual  motion 

device - must be installed in the position shown in figure 4. In the 

absence of the winch, the operator can be installed in any position.

If you wish to install the remote release control, first check that the 

release lever does not interfere with the operator’s external parts. 

The securing plate can be installed on any of the operator’s two 

sides.

 

5.3 INSTALLING THE OPERATOR 

•Release the operator with the appropriate lever. 

•Fit the securing plate on the operator without tightening the screws. 

•Engage the power take-off on the drive shaft. 

•Position the operator (see paragraph 5.1) and rest the plate on 

the support (wall or metal structure) on which you have decided 

to secure it (see figure 6.). 

•Tighten the screws without forcing them, while resting the plate 

on the support. 

•Trace the position of the installation holes. 

•Remove the operator. 

•Carry out the securing preparation work.

•Insert the first key securing bush and the key itself in the shaft (see 

fig.2 ref. 8 and 9).

•Re-install the operator with the plate released. 

•Secure  the plate to the support, tighten the fastening screws on 

the operator to a maximum torque of 18Nm and insert the second 

key securing bush. 

•Secure the two bushes after positioning them in contact with the 

operator’s power take-off. 

•Lock the operator. 

If you wish to weld the securing plate to the support, do the wel

-

ding with the operator uninstalled, and protect the drive shaft in 

the power take-off engagement zone. If the operator cannot be 

removed, it must be protected.

Fig. 6

Fig. 4

Summary of Contents for 541 3ph

Page 1: ...541 3ph 541 3ph...

Page 2: ...r any deformation that may occur during use 10 The installation must conform to Standards EN 12453 and EN 12445 For non EU countries to obtain an adequate level of safety the Standards mentioned above...

Page 3: ...ced industrial sectional doors They consist of an electro mechanical operator with on board 541D inter connection board for remote control unit 844T Installation is possible either directly on the sha...

Page 4: ...2x0 5 Tx photocells Low voltage cabling radio receiver Low voltage cabling 6x0 5 control panel Equipment enclosure Operator Power take off Securing plate Limit switch unit Winch in models for which it...

Page 5: ...port wall or metal structure on which you have decided to secure it see figure 6 Tighten the screws without forcing them while resting the plate on the support Trace the position of the installation h...

Page 6: ...ee figure 9 so that the winch support disappears completely inside the plastic enclosure see figure 10 Check if the traction of just one of the chain sections causes the winch to engage and if the win...

Page 7: ...hat the operator actually reaches the desired positions when opening and closing If this does not occur correct the limit switch positions using trimmer 1 If used with 578D equipment you can correct t...

Page 8: ...locked operator and the relevant positions of the release ropes with red knob and locking ropes with green knob Fit the lever and make sure that it reaches the travel limits in the two directions at...

Page 9: ...cables The 541 3ph operator is supplied with an on board inter connection board 6 1 CONNECTIONS OF 844T ELECTRONIC EQUIPMENT Lay the raceways according to the instructions in figure 4 Make the connec...

Page 10: ...the equipment activates the electric motor which drives the door to opening position to permit access In dead man systems the command push button must be kept pressed for the whole duration of the ope...

Page 11: ......

Page 12: ...ldungen in vorliegendem Handbuch sind unverbindlich FAAC beh lt sich das Recht vor ohne die wesentlichen Eigenschaften dieses Ger tes zu ver ndern und ohne Verbindlichkeiten in Bezug auf die Neufassun...

Reviews: