background image

3

 

cause severe injury and/or death, for which the 
manufacturer cannot be held responsible. 

4.  The installer must provide a main power switch that 

meets all applicable safety regulations. 

5.  Clearly indicate on the gate with a minimum of 2 

warning signs (visible from either side of the gate) 
that indicate the following:  

• 

The gate is automatic and could move at 
any time, posing a serious risk of 
entrapment.  

• 

Children should not be allowed to operate 
the gate or play in the gate area. 

• 

The gate should be operated only when it 
is visible to the operator and the when the 
area is free of people and obstructions. 

6.  It is extremely unsafe to compensate for a damaged 

gate by overtightening a clutch or increasing 
hydraulic pressure. 

7.  Devices such as reversing edges and photocells 

must be installed to provide better protection for 
personal property and pedestrians. Install reversing 
devices that are appropriate to the gate design and 
gate application. 

8.  Before applying electrical power, be sure that the 

voltage requirements of the equipment correspond 
to your supply voltage. Refer to the label on your 
operator system. 

Use 

1.  Use this equipment only in the capacity for which it 

was designed. Any use other than that stated should 
be considered improper and therefore dangerous. 

2.  When using any electrical equipment, observe 

some fundamental rules:  

• 

Do not touch the equipment with damp or 
humid hands or feet. 

• 

Do not install or operate the equipment 
with bare feet. 

• 

Do not allow small children or incapable 
persons to use the equipment. 

3.  If a gate system component malfunctions, turn off 

the main power before making any attempt to repair 
it. 

4.  Do not attempt to impede the movement of the 

gate. You may injure yourself as a result. 

5.  This equipment may reach high temperatures 

during operation; therefore, use caution when 
touching the external housing of the operator. 

6.  Learn to use the manual release mechanism 

according to the procedures found in this in-
stallation manual. 

7.  Before carrying out any cleaning or maintenance 

operations, disconnect the equipment from the 
electrical supply.  

8.  To guarantee the efficiency of this equipment, the 

manufacturer recommends that qualified personnel 
periodically check and maintain the equipment. 

 

U.L. Class and FAAC Operator 

Model 

Duty Cycle 

Typical Use 

Class I: Residential Vehicular Gate Operator 

 402 

750 

 422 

760 

 412 

 

Limited duty 

• 

Home use 

• 

Small apartment building, for example, up to 4 units 
in a building, with limited public access 

Class II: Commercial/General Access Vehicular Gate Operator 

 400 

640 

 620 

 

Continuous duty 

• 

Apartment buildings 

• 

Very public access 

Class III: Industrial/Limited Access Vehicular Gate Operator 

 400 

640 

 620 

Continuous duty 

• 

No public access 

Class IV: Restricted Access Vehicular Gate Operator 

 620 

640 

Continuous 

duty 

• 

Prison rated security 

 

 

Summary of Contents for 412 Compact

Page 1: ...ate Leaf 10 Attach the Rear Mounting Bracket 10 Attach the Operator to the Rear Mounting Bracket 12 Attach the Operator to the Front Mounting Bracket 12 Attach the Front Mounting Bracket to the Gate L...

Page 2: ...ortant that you locate the gate far enough away from the road to eliminate the potential of traffic getting backed up This distance is affected by the size of the gate how often it is used and how fas...

Page 3: ...al equipment observe some fundamental rules Do not touch the equipment with damp or humid hands or feet Do not install or operate the equipment with bare feet Do not allow small children or incapable...

Page 4: ...may affect duty cycle 4 The 90 deg opening time for a gate with the 412 Operator is a maximum of about 46 sec Note that both the mounting dimensions and the torque adjustment help to determine the pr...

Page 5: ...is marked SX and one is marked DX Be sure to install each on the proper gate leaf see Figure 2 2 Protective covers for the worm screw housing of the operator 1 Package of mounting hardware 2 Rear mou...

Page 6: ...on the single phase bidirectional motor shuts off automatically if its operating temperature reaches 284 deg F 140 deg C Also for the protection and proper operation of the 412 Operator each gate leaf...

Page 7: ...e 450 MPS control panel are briefly described below You can find a complete description of each logic in the tables on the following pages A automatic The gate opens on command and automatically close...

Page 8: ...them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Opening Closes both leaves immediately Closes the leaf immediately Stops S...

Page 9: ...1 No effect opening is inhibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device no longer triggered No effect On O...

Page 10: ...Installing the operator consists of the following steps Establishing the orientation of each gate leaf and its operator Attaching the rear mounting bracket Attaching the operator to the rear mounting...

Page 11: ...acket see Figure 6 The recessed liner should be constructed of 3 16 or 1 4 in steel with a minimum interior height of 11 13 16 in 30 cm so as to allow you to meet the required dimensions shown in Figu...

Page 12: ...gate installation Inward swinging Lengthen the worm screw completely and push the cylinder in one inch Outward swinging Shorten the worm screw completely and then pull the cylinder out one inch With t...

Page 13: ...unting plate to the center of the front mounting hole on the operator Figure 9 Secure the operator to the front mounting bracket with the short pin and 2 snap rings dimensions are incorrect see Figure...

Page 14: ...WARNING The voltage of the main power must match the required voltage of the 412 Operator and the 450 MPS control panel Wire the main power supply to control panel terminals in block J1 see Figures 13...

Page 15: ...the control panel enclosure For the purposes of installation you need to connect at least one normally open N O activating device for your operator s If you have a two leaf gate design connect the ac...

Page 16: ...Listed cord grip Junction box Op 1 Op 2 1 2 3 4 5 6 7 8 OP COM CL CL COM OP Lamp Motor 1 Motor 2 J1 J2 High voltage terminal strip 450 MPS Control Panel U L Listed Control Panel Enclosure Cord grip or...

Page 17: ...tially dangerous Do not place yourself within the path of the moving gate during your test Disengage the operator s with the Manual Release key and open the gate by hand about halfway Next engage the...

Page 18: ...on terminal block J3 requires a fail safe connection for the photocells Connect the photocells to terminals 20 and 21 in the FSWTX grouping Activating Devices and Radio Receiver The acti vating device...

Page 19: ...button you must install a circuit between these terminals for the control panel to work The LED Indicators The five light emitting diodes LEDs on the control panel can be used to check for the proper...

Page 20: ...ol Panel has 5 DIP switches and 4 potentiometers that control a wide range of functions Set DIP Switches Switches 1 2 and 3 Operating Logic The 450 MPS Control Panel offers six operating modes A S E E...

Page 21: ...5 sec Note You cannot adjust this opening delay of the operator connected to Motor 2 However you can avoid the opening delay and closing delay by connecting both operators and their capacitors to Mot...

Page 22: ...k J3 Check the LED DL1 for a two leaf gate or DL2 for a one leaf gate One of them should turn on when you signal the gate to open or to close If neither one illuminates then check the wiring for the a...

Page 23: ...negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding...

Reviews: