background image

 

 

 

 

 

 

 

 

 

Limited Warranty 

 

To the original purchaser only:

 FAAC International, Inc., warrants, for twelve (12) months from the date of invoice, the gate 

operator systems and other related systems and equipment manufactured by FAAC S.p.A. and distributed by FAAC International, 
Inc., to be free from defects in material and workmanship under normal use and service for which it was intended 

provided

 it has 

been properly installed and operated. FAAC International, Inc.'s obligations under this warranty shall be limited to the repair or 
exchange of any part of parts manufactured by FAAC S.p.A. and distributed by FAAC International, Inc. Defective products must 
be returned to FAAC International, Inc., freight prepaid by purchaser, within the warranty period. Items returned will be repaired or 
replaced, at FAAC International, Inc.'s option, upon an examination of the product by FAAC International, Inc., which discloses, to 
the satisfaction of FAAC International, Inc., that the item is defective. FAAC International, Inc. will return the warranted item 
freight prepaid. The products manufactured by FAAC S.p.A. and distributed by FAAC International, Inc., are not warranted to meet 
the specific requirements, if any, of safety codes of any particular state, municipality, or other jurisdiction, and neither FAAC S.p.A. 
or FAAC International, Inc., assume any risk or liability whatsoever resulting from the use thereof, whether used singly or in 
combination with other machines or apparatus. 
 

Any products and parts not manufactured by FAAC S.p.A. and distributed by FAAC International, Inc., will carry only the 

warranty, if any, of the manufacturer. This warranty shall not apply to any products or parts thereof which have been repaired or 
altered, without FAAC International, Inc.'s written consent, outside of FAAC International, Inc.'s workshop, or altered in any way 
so as, in the judgment of FAAC International, Inc., to affect adversely the stability or reliability of the product(s) or has been 
subject to misuse, negligence, or accident, or has not been operated in accordance with FAAC International, Inc.'s or FAAC S.p.A.'s 
instructions or has been operated under conditions more severe than, or otherwise exceeding, those set forth in the specifications for 
such product(s). Neither FAAC S.p.A. or FAAC International, Inc., shall be liable for any loss or damage whatsoever resulting, 
directly or indirectly, from the use or loss of use of the product(s). Without limiting the foregoing, this exclusion from liability 
embraces a purchaser's expenses for downtime or for making up downtime, damages for which the purchaser may be liable to other 
persons, damages to property, and injury to or death of any persons. Neither FAAC S.p.A. or FAAC International, Inc., assumes nor 
authorizes any person to assume for them any other liability in connection with the sale or use of the products of FAAC S.p.A. or 
FAAC International, Inc. The warranty hereinabove set forth shall not be deemed to cover maintenance parts, including, but not 
limited to, hydraulic oil, filters, or the like. No agreement to replace or repair shall constitute an admission by FAAC S.p.A. or 
FAAC International, Inc., of any legal responsibility to effect such replacement, to make such repair, or otherwise. This limited 
warranty extends only to wholesale customers who buy directly through FAAC International, Inc.'s normal distribution channels. 
FAAC International, Inc., does not warrant its products to end consumers. Consumers must inquire from their selling dealer as to 
the nature and extent of that dealer's warranty, if any. 

 

This warranty is expressly in lieu of all other warranties expressed or implied including the warranties of 

merchantability and fitness for use. This warranty shall not apply to products or any part thereof which have 
been subject to accident, negligence, alteration, abuse, or misuse or if damage was due to improper installation 
or use of improper power source, or if damage was caused by fire, flood, lightning, electrical power surge, 
explosion, wind storm, hail, aircraft or vehicles, vandalism, riot or civil commotion, or acts of God.

 

 

FAAC International, Inc.

 

303 Lexington Avenue

 

Cheyenne, WY  82007 

412 IM, 9/98

 

Summary of Contents for 412 Compact

Page 1: ...ate Leaf 10 Attach the Rear Mounting Bracket 10 Attach the Operator to the Rear Mounting Bracket 12 Attach the Operator to the Front Mounting Bracket 12 Attach the Front Mounting Bracket to the Gate L...

Page 2: ...ortant that you locate the gate far enough away from the road to eliminate the potential of traffic getting backed up This distance is affected by the size of the gate how often it is used and how fas...

Page 3: ...al equipment observe some fundamental rules Do not touch the equipment with damp or humid hands or feet Do not install or operate the equipment with bare feet Do not allow small children or incapable...

Page 4: ...may affect duty cycle 4 The 90 deg opening time for a gate with the 412 Operator is a maximum of about 46 sec Note that both the mounting dimensions and the torque adjustment help to determine the pr...

Page 5: ...is marked SX and one is marked DX Be sure to install each on the proper gate leaf see Figure 2 2 Protective covers for the worm screw housing of the operator 1 Package of mounting hardware 2 Rear mou...

Page 6: ...on the single phase bidirectional motor shuts off automatically if its operating temperature reaches 284 deg F 140 deg C Also for the protection and proper operation of the 412 Operator each gate leaf...

Page 7: ...e 450 MPS control panel are briefly described below You can find a complete description of each logic in the tables on the following pages A automatic The gate opens on command and automatically close...

Page 8: ...them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Opening Closes both leaves immediately Closes the leaf immediately Stops S...

Page 9: ...1 No effect opening is inhibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device no longer triggered No effect On O...

Page 10: ...Installing the operator consists of the following steps Establishing the orientation of each gate leaf and its operator Attaching the rear mounting bracket Attaching the operator to the rear mounting...

Page 11: ...acket see Figure 6 The recessed liner should be constructed of 3 16 or 1 4 in steel with a minimum interior height of 11 13 16 in 30 cm so as to allow you to meet the required dimensions shown in Figu...

Page 12: ...gate installation Inward swinging Lengthen the worm screw completely and push the cylinder in one inch Outward swinging Shorten the worm screw completely and then pull the cylinder out one inch With t...

Page 13: ...unting plate to the center of the front mounting hole on the operator Figure 9 Secure the operator to the front mounting bracket with the short pin and 2 snap rings dimensions are incorrect see Figure...

Page 14: ...WARNING The voltage of the main power must match the required voltage of the 412 Operator and the 450 MPS control panel Wire the main power supply to control panel terminals in block J1 see Figures 13...

Page 15: ...the control panel enclosure For the purposes of installation you need to connect at least one normally open N O activating device for your operator s If you have a two leaf gate design connect the ac...

Page 16: ...Listed cord grip Junction box Op 1 Op 2 1 2 3 4 5 6 7 8 OP COM CL CL COM OP Lamp Motor 1 Motor 2 J1 J2 High voltage terminal strip 450 MPS Control Panel U L Listed Control Panel Enclosure Cord grip or...

Page 17: ...tially dangerous Do not place yourself within the path of the moving gate during your test Disengage the operator s with the Manual Release key and open the gate by hand about halfway Next engage the...

Page 18: ...on terminal block J3 requires a fail safe connection for the photocells Connect the photocells to terminals 20 and 21 in the FSWTX grouping Activating Devices and Radio Receiver The acti vating device...

Page 19: ...button you must install a circuit between these terminals for the control panel to work The LED Indicators The five light emitting diodes LEDs on the control panel can be used to check for the proper...

Page 20: ...ol Panel has 5 DIP switches and 4 potentiometers that control a wide range of functions Set DIP Switches Switches 1 2 and 3 Operating Logic The 450 MPS Control Panel offers six operating modes A S E E...

Page 21: ...5 sec Note You cannot adjust this opening delay of the operator connected to Motor 2 However you can avoid the opening delay and closing delay by connecting both operators and their capacitors to Mot...

Page 22: ...k J3 Check the LED DL1 for a two leaf gate or DL2 for a one leaf gate One of them should turn on when you signal the gate to open or to close If neither one illuminates then check the wiring for the a...

Page 23: ...negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding...