background image

|   English

4

SPP 800X - SPP 1200X - SPP 800

SAFETY MEASURES

Read carefully the operating instructions 

before assembling and starting. The appli-

ance must not be used by operators who 

are not thoroughly acquainted with the 

instructions handbook (operating instruc-

tions). Moreover, the appliance must not be 

used by persons under the age of 16.

 

f

The  user  is  liable  towards  third  parties  in  the  area 

where the appliance is in operation.

 

f

Before starting it is necessary to check that the nec

-

essary  electrical  protection  measures  are  met,  by 

means of a test carried out by a specialist.

While the pump is operating, no person 

should be in the liquid. The pump may be 

connected only by means of a safety switch 

for fault currents, with an opening rated 

current up to 30 mA and a socket with an 

earth contact in compliance with the reg-

ulations.

Protection: at least 10 Amps. 

Operation  in  swimming  pools  and  garden 

ponds is not recommended.

 

CAUTION: Before checking, unplug the 

pump from the mains! 

Replacing the power supply cable requires using 

special  tools  and  therefore  you  must  address  to 

the authorized after-sales service.

The pump may only operate with an extension ob

-

tained through cable mod. H07 RNF and a thread 

section of no less than 1 mm in compliance with 

the DIN 57282 or DIN 57245 standard.

 

f

The noise (continuous equivalent in dbA) of the mo

-

tor-driven pumps is less or equal (≤) to 85 dbA.

 

f

The voltage (230 Volts alternating current) indicated 

on  the  pump  rating  plate  must  correspond  to  the 

available mains voltage.

 

f

The  temperature  of  the  liquid  conveyed  must  not 

exceed 35

ο

C.

 

f

Never attempt to lift or move the pump by stretch

-

ing the power-supply cable whilst it is plugged into 

the mains.

 

f

Make  sure  that  the  plugged  electrical  connections 

are in an area safe from flooding and are protected 

from humidity.

 

f

Before use it is necessary to check that the plug and 

the mains connection line are not damaged.

 

f

Unplug from the mains before performing any work 

on the pump.

 

f

Avoid directly exposing the pump to the jet of water.

 

f

The user is responsible for complying with the local 

regulations concerning assembly and safety.

 

f

The user by taking appropriate measures (e.g. install

-

ing an alarm, reserve pump and the like) will have to 

exclude the possibility of indirect damage caused by 

flooding premises due to failure of the pump.

ENGLISH

 

f

In  the  event  of  the  pump  failing,  repair  work  may 

only be carried out by the repair workshops of the 

authorized  service.  Only  genuine  spare  parts  must 

be used.

 

f

It is notified that in conformity with the law on prod

-

uct  liability  we  cannot  be  held  responsible  for  the 

damage caused by our appliance:

1.  Because of improper repairs not carried out by 

the  personnel  of  the  assistance  points  autho

-

rized by us; or

2.  If  GENUINE  SPARE  PARTS  are  not  used  to  re

-

place parts; or

3.  If  the  indications  and  provisions  given  in  the 

instructions handbook are not complied with.

The same provisions hold for the accessories.

RESISTANCE

This  pump  should  not  be  used  to  convey  inflam

-

mable, combustible or explosive liquids.

TECHNICAL DATA

Article Number

43 483

43 484

43 485

Model

SPP 

800X

SPP 

1200X

SPP 

800

Voltage / 

Frequence

V

230

230

230

Hz

50

50

50

Rated Power

W

800

1200

800

Max. height

m

38

46

38

Max.

flow rate

L/h

3200

3700

3500

Max.suction 

height

m

8

8

8

Max. Grain 

Size

mm

1

1

1

Diameter of 

Connecting 

Pipe

1”

1”

1”

Max. 

Pressure

bar

3,8

4,6

3,8

Max. Noise

dB

85

85

85

Max.media 

temperature

o

C

35

35

35

Cable Lenght

m

1

1

1

Weight

kg

6,4

7,7

6,4

Protection

IPX4

IPX4

IPX4

Insulation 

Class

B

B

B

Summary of Contents for SPP 800X

Page 1: ...ORIGINAL INSTRUCTIONS EN NOTICE ORIGINALE FR ISTRUZIONI ORIGINALI IT EL ORIGINALNO UPUTSTVO ZA RAD SR INSTRUC IUNI DE FOLOSIRE ORIGINALE RO BG ORIGINALNE UPUTE ZA RAD HR SPP 800X SPP 1200X SPP 800...

Page 2: ...ELETTROPOMPA JET SS 43485 ELETTROPOMPA JET 08 EL 43483 43484 JET INOX 43485 JET 10 SR 43483 43484 PUMPA JET SS 43485 PUMPA JET 12 HR 43483 43484 CRPKA JET SS 43485 CRPKA JET 14 RO 43483 43484 POMP JE...

Page 3: ...3 www ffgroup tools com SPP 800X SPP 1200X SPP 800...

Page 4: ...it is plugged into the mains f Make sure that the plugged electrical connections are in an area safe from flooding and are protected from humidity f Before use it is necessary to check that the plug...

Page 5: ...before turning back on If there is a risk of frost the pump has to be emp tied completely When the pump is not going to be used for a long time for instance in the winter period it is recom mended to...

Page 6: ...e d alimentation branch au r seau f Assurez vous que les branchements lectriques se trouvent l abri des inondations et de l humidit f Avant l utilisation v rifiez si la ligne de branche ment au r seau...

Page 7: ...remonter soi gneusement remettre les filtres correctement et effectuer la mise en service En cas de risque de gel la pompe doit tre com pl tement vid e Avant une longue p riode d inutilisation de la...

Page 8: ...ne collegato alla rete f Assicurarsi che le connessioni elettriche a spina si trovino in una zona sicura da allagamenti e siano pro tette dall umidit f Prima dell uso occorre verificare che la linea d...

Page 9: ...ltri in modo corretto ed effettuare la messa in funzione In caso di pericolo di gelo la pompa deve essere svuotata completamente Prima di un lungo periodo di inutilizzo della pom pa per es nel periodo...

Page 10: ...F 1mm DIN 57282 DIN 57245 f dbA 85 dbA f 230 Volt f 35 C f f f f f f f f f 1 2 3 43 483 43 484 43 485 SPP 800X SPP 1200X SPP 800 V 230 230 230 Hz 50 50 50 W 800 1200 800 m 38 46 38 L h 3200 3700 3500...

Page 11: ...11 www ffgroup tools com SPP 800X SPP 1200X SPP 800 o C 35 35 35 m 1 1 1 kg 6 4 7 7 6 4 IPX4 IPX4 IPX4 B B B 30 2002 96...

Page 12: ...ok je uklju en u struju f Proverite da li se priklju eni elektri ni priklju ci nalaze u podru ju koje je bezbedno od poplavljivanja i za ti eno od vlage f Pre upotrebe je neophodno proveriti da li su...

Page 13: ...vite i vratite filtere na mesto pre ponovnog uklju ivanja Ako postoji rizik od mraza pumpu treba potpuno isprazniti Kada se pumpa ne koristi u du em preriodu na primer tokom zime preporu uje se da je...

Page 14: ...i priklju ci nalaze u podru ju koje je sigurno od poplave i za ti eno od vlage f Prije upotrebe provjerite da utika i vod elektri nog napajanja nisu o te eni f Iskop ajte utika iz uti nice prije izvo...

Page 15: ...filtre prije ponovnog uklju ivanja Ako postoji rizik od zamrzavanja crpku je potreb no potpuno isprazniti Ako crpku ne ete koristiti neko vrijeme primjerice zimi preporu ujemo da temeljito isperete cr...

Page 16: ...priz sunt ntr o zon ferit de riscul de inunda ii i sunt protejate de umiditate f naintedeutilizareestenecesars verifica idac te cherul i circuitul de alimentare nu sunt deteriorate f Deconecta i de l...

Page 17: ...ct nainte s porni i din nou pompa Dac exist un risc de nghe pompa trebuie go lit integral C nd pompa nu va fi folosit o perioad ndelun gat de exemplu n perioada de iarn se reco mand cl tirea pompei cu...

Page 18: ...NF 1 DIN 57282 DIN 57245 f dbA 85 dbA f 230 f 35 C f f f f f f f f f 1 2 3 43 483 43 484 43 485 SPP 800X SPP 1200X SPP 800 V 230 230 230 Hz 50 50 50 W 800 1200 800 m 38 46 38 L h 3200 3700 3500 m 8 8...

Page 19: ...19 www ffgroup tools com SPP 800X SPP 1200X SPP 800 m 1 1 1 kg 6 4 7 7 6 4 IPX4 IPX4 IPX4 B B B 30 2002 96 EO OEEO...

Page 20: ...trigger again approx 20 mins FRAN AIS R SOLUTION DES PROBL MES PROBL ME CAUSES REMEDIES Le moteur ne d marre pas Absence alimentation lectrique Couronne pompe bloqu e Thermostat d branch V rifier l a...

Page 21: ...a valvola aspirante min 30cm Versare acqua nel raccordo aspir Verificare la tenuta del tubo aspir Pulire la valvola aspirante Pulire il filtro Controllare l altezza di aspirazione Portata insufficient...

Page 22: ...e pumpu i zamenite dotrajale delove Pumpu isklju uje za tita od pregrevanja Preoptere enje motora Prekomerno trenje je izazvano stranim telima Elimini ite strana tela Sa ekajte da se ponovo aktivira p...

Page 23: ...ra ie min 30 cm A se turna ap n racordul de aspira ie Se verifica etanseitatea circuitului de aspira ie A se cur a supapa de aspira ie A se cur a filtrul A se controla n l imea de aspira ie Debit insu...

Page 24: ...uenti Normative 43 483 43 484 ELETTROPOMPA JET SS 43 485 ELETTROPOMPA JET Codice prodotto EL 43 483 43 484 JET INOX 43 485 JET SR EU IZJAVA O USAGLA ENOSTI Na sopstvenu odgovornost izjavljujemo da nav...

Page 25: ...1 2012 A11 A13 EN60335 2 41 2003 A1 A2 EN 62233 2008 EN Technical file at FF GROUP TOOL INDUSTRIES 19300 Aspropyrgos Greece Loudovikos Tsirigiotis Operations Engineering FF GROUP TOOL INDUSTRIES 1930...

Page 26: ...26 SPP 800X SPP 1200X SPP 800...

Page 27: ...27 www ffgroup tools com SPP 800X SPP 1200X SPP 800...

Page 28: ...www ffgroup tools com info ffgroup toolindustries com 30 210 55 98 400 19300 Athens Greece 9 5 Km Attiki Odos Aspropyrgos FF GROUP TOOL INDUSTRIES...

Reviews: