PIPES

Secure all pipes to support so that they do not carry 

on stress, strain or vibration to the pump.

The  inner  pipe  diameter  depends  on  the  capacity 

required. If possible, diameter has to enable a liquid 

speed  not  higher  than  1.5m/s  during  suction  and 

3m/s during delivery. The pipe diameters never have 

to be smaller than the pump connections.

The suction pipe must be perfectly airtight and be 

led upwards in order to avoid air pockets. For suc-

tion  operation  fit  a  strainer-equipped  valve,  which 

must always be immersed.

For suction from a storage tank fit a check valve. For 

positive suction head operation fit a gate valve. Fol-

low local specifications if increasing network pres-

sure. Fit a gate valve into the delivery pipe to adjust 

delivery, head, and absorbed power.

Install  a  pressure  gauge.  With  a  geodetic  head  at 

outlet over 15m fit a check valve between the pump 

and  the  gate  valve  in  order  to  protect  the  pump 

from  water  hammering.  Ensure  the  inner  sides  of 

the pipes are clean before connection.

ELECTRICAL CONNECTION

Electrical connection must be carried out by a qual-

ified electrician in compliance with local regulation. 

The  unit  must  be  properly  earthed  (grounded). 

Position the terminals following the instructions 

written on in the plate, which is placed inside the 

capacitor  box.  Install  a  device  for  disconnection 

from  the  supply,  having  a  contact  separation  of 

at least 3mm in all poles. Single phase pumps are 

supplied  with  a  capacitor  connected  to  the  ter-

minals and with inset thermal protector for 220-

230V - 50Hz.

START-UP

Check that the shaft turns by hand. For this pur-

pose the smaller pumps have a screwdriver notch 

on the ventilation side of the shaft end. Never run 

the pump dry.

Start  the  pump  after  filling  it  up  with  liquid 

through the relevant priming hole.

When operating under positive suction head, fill 

the pump by opening the suction gate valve slow-

ly and completely, keeping the delivery gate valve 

open to release the air.

With three phase motor check that the direction 

of rotation is as shown by the arrow on the pump 

casing; otherwise reverse the connections of the 

phases.

Check that the pump works within its field of per-

formance,  and  that  the  absorbed  current  shown 

on the name plate is not exceeded.

Otherwise  adjust  the  delivery  gate  valve,  or  the 

sitting of any pressure switches.

MAINTENANCE

When the pump is not used, empty it completely if 

freezing may be expected.

Before restarting the pump, check that the shaft 

is not jammed from incrustations or other causes 

and fill the pump casing completely with liquid. 

CAUTION:

 

disconnect the mains before any ser-

vicing operation.

ENVIRONMENTAL PROTECTION

Information on the disposal of electric and 

electronic  equipment  in  compliance  with 

directive 2002/96 CE (RAEE).

Warning: do not use the normal house trash 

bin to dispose of this product.

Used  electric  and  electronic  equipment 

must be handled separately and in compli-

ance  with  the  regulations  relating  to  the 

treatment,  recovery  and  recycling  of  the 

said products.

In accordance with the regulations applied 

in  the  member  States,  private  users  resi-

dent  in  the  EU  can  take  used  electric  and 

electronic equipment free of charge to des-

ignated collection centers.

If  you  experience  difficulties  in  locating 

an  authorized  disposal  center,  consult  the 

dealer from whom you purchased the prod-

uct.

The national regulations provide sanctions 

against whoever unlawfully disposes of or 

abandons  waste  of  electric  or  electronic 

equipment.

GUARANTEE

This product is warranted in accordance with the le-

gal/country specific regulations, effective from the 

date of purchase by the first user. Damage attribut-

able to normal wear and tear, overload or improper 

handling  will  be  excluded  from  the  guarantee.  In 

case of a claim, please send the machine, complete-

ly assembled, to your dealer or the service center for 

electric power tools.

Summary of Contents for CWP 500

Page 1: ...ORIGINAL INSTRUCTIONS EN NOTICE ORIGINALE FR ISTRUZIONI ORIGINALI IT EL ORIGINALNO UPUTSTVO ZA RAD SR INSTRUC IUNI DE FOLOSIRE ORIGINALE RO BG ORIGINALNE UPUTE ZA RAD HR CWP 500 CWP 1000...

Page 2: ...PE A EAU CENTRIFUGEUSE 06 IT ELETTROPOMPA CENTRIFUGA 08 EL 10 SR CENTRIFUGALNA PUMPA ZA VODU 12 HR CENTRIFUGALNA CRPKA ZA VODU 14 RO POMP CENTRIFUGAL DE AP 16 BG 18 TROUBLESHOOTING R SOLUTION DES PROB...

Page 3: ...English 3 www ffgroup tools com CWP 500 CWP 1000...

Page 4: ...spare parts must be used f f It is notified that in compliance with the law on product liability we cannot be held responsible for the damages caused by our appliance 1 Because of improper repairs no...

Page 5: ...er positive suction head fill the pump by opening the suction gate valve slow ly and completely keeping the delivery gate valve open to release the air With three phase motor check that the direction...

Page 6: ...nce de la pompe f f En cas de d faillance de la pompe les travaux de r paration ne peuvent tre effectu s que par les ateliers du service technique Seules des pi ces de rechange d origine doivent tre u...

Page 7: ...n cette fin les pompes plus petites comportent une encoche pour un tournevis situ e l extr mit de l arbre sur le c t ventilation Ne jamais faire fonctionner la pompe sec Allumez la pompe apr s l avoir...

Page 8: ...anno essere eseguiti solo dalle of ficine di riparazione del servizio assistenza Devono essere usati solo pezzi di ricambio originali f f Si avverte che ai sensi della legge sulla responsabili t del p...

Page 9: ...dopo averla riempita con liquido attraverso l apposito foro Con il funzionamento sotto battente riempire la pompa aprendo lentamente e completamente la valvola a saracinesca nel tubo aspirante tenend...

Page 10: ...2 3 42922 42923 CWP 500 CWP 1000 V 220 230 220 230 Hz 50 50 hp 0 50 1 00 W 370 750 W 500 1 000 dB A 75 75 bar 2 00 3 00 m 20 30 m3 h 4 8 6 DN 1 inch 1 1 2 inch 1 1 mm 63 71 L60 L80 Kg 8 3 11 25 rpm 2...

Page 11: ...11 www ffgroup tools com CWP 500 CWP 1000 1 5m s 3 m s 5 15 3mm 220 230 V 50 Hz 2002 96...

Page 12: ...ju se koristiti isklju ivo originalni delovi f f Podse amo da u skladu sa zakonom o odgovornosti za proizvode ne mo emo biti odgovorni za tete na stale na im ure ajem 1 Zbog nepravilnih popravki koje...

Page 13: ...tpunosti napu nite te no u kroz odgovaraju i usisni otvor Kada radi pod pozitivnim usisnim naporom napu nite pumpu tako to ete polako otvarati propusni ventil na usisu odr avaju i otvor propusnog ven...

Page 14: ...Upotrebljavati se smiju samo originalni dijelovi f f Napominjemo da u sukladnosti sa zakonom o odgo vornosti za proizvod ne mo emo snositi odgovor nost za tete koje prouzro i na ure aj 1 Zbog nepropis...

Page 15: ...raditi na suho Pokrenite crpku nakon to se napuni teku inom putem odgovaraju e rupe za punjenje Prilikom rada s pozitivnom usisnom glavom crpku napunite tako da polako i do kraja otvorite usisni propu...

Page 16: ...pompei lucr rile de repara ii pot fi efectuate numai de atelierele de repara ii ale departamentului tehnic Trebuie folosite doar com ponente originale f f Este de men ionat faptul c n conformitate cu...

Page 17: ...pu ne i niciodat n func iune pompa n stare uscat Porni i pompa dup umplerea sa complet cu li chid prin orificiul de acces corespunz tor C nd pune i n func iune capul de aspirare cores punz tor umple...

Page 18: ...2 3 42922 42923 CWP 500 CWP 1000 V 220 230 220 230 Hz 50 50 hp 0 50 1 00 W 370 750 W 500 1 000 dB A 75 75 bar 2 00 3 00 m 20 30 m3 h 4 8 6 DN 1 inch 1 1 2 inch 1 1 mm 63 71 L60 L80 Kg 8 3 11 25 rpm 2...

Page 19: ...19 CWP 500 CWP 1000 www ffgroup tools com 1 5 3 15 3 220 230V 50Hz 2002 96 EO OEEO...

Page 20: ...Pump intake valve in water No water in pump body Pour water into the suction pipe until it is full Air in suction pipe Remove the air from the suction pipe Intake valve leaks Clean valve thoroughly I...

Page 21: ...la pompe Versez de l eau dans la conduite d aspiration jusqu ce qu elle soit pleine Air dans le tuyau d aspiration Retirez l air de la conduite d aspiration Fuite de la vanne d admission Nettoyez la...

Page 22: ...ubo di aspirazione fino a riempirlo Aria nel tubo di aspirazione Estrarre l aria dal tubo di aspirazione La valvola di aspirazione perde Pulire a fondo la valvola Valvola di aspirazione ostruita Pulir...

Page 23: ...23 www ffgroup tools com CWP 500 CWP 1000...

Page 24: ...il pumpe je u vodi Nema vode u ku i tu pumpe Sipajte vodu u usisnu cev dok se ne napuni Vazduh u usisnoj cevi Uklonite vazduh iz usisne cevi Usisni ventil curi Temeljno o istite ventil Usisni ventil j...

Page 25: ...u vodi U ku i tu crpke nema vode Ulijevajte vodu u usisnu cijev dok se ne napuni Zrak u usisnoj cijevi Uklonite zrak iz usisne cijevi Usisna cijev propu ta Dobro o istite ventil Usisni ventil je za e...

Page 26: ...na i ap n eava de aspira ie p n se umple Exist aer n conducta de aspirare Elimina i aerul din eava de aspira ie Supapa de admisie prezint scurgeri Cur a i supapa cu aten ie Supapa de admisie este nfun...

Page 27: ...27 CWP 500 CWP 1000 www ffgroup tools com...

Page 28: ...navedeni proizvo di odgovaraju svim doti nim odredbama naknadno navedenih smernica u uredaba i da su u skladu sa slede im standardima CENTRIFUGALNA PUMPA ZA VODU Broj predmeta HR EU IZJAVA O SUKLADNOS...

Page 29: ...0 Aspropyrgos Greece Loudovikos Tsirigiotis Operations Engineering FF GROUP TOOL INDUSTRIES S A 19300 Aspropyrgos Greece 3 12 2018 FR Dossier technique aupr s de IT Fascicolo tecnico presso EL SR Tehn...

Page 30: ...30 CWP 500 CWP 1000...

Page 31: ...31 CWP 500 CWP 1000 www ffgroup tools com...

Page 32: ...www ffgroup tools com info ffgroup toolindustries com 30 210 55 98 400 19300 Athens Greece 9 5 Km Attiki Odos Aspropyrgos FF GROUP TOOL INDUSTRIES...

Reviews: