As the arms come out, the hydraulic fluid level in the pump reser-
voir will drop towards the bottom indentation in the reservoir
(indicated by the red line in the illustration). Allowing the fluid
level to drop below the bottom indentation may lead to air enter-
ing the system. As the level approaches the bottom indentation
release the “Boom Out” button to stop the arms. Use the hydrau-
lic fluid provided to refill the reservoir up to the level of the top
reservoir indentation indicated by the black line in the illustration.
MOUNT THE WINCH CROSSBAR
Back out the three screws that secure the Winch Terminal Block
Cover. Remove the cover and set it aside.
Place the crossbar in the arm
bracket on the passenger side
and do not secure.
A fish lead will extend out of the Winch Power
Cable Feed Hole on the driver’s side of the cross
bar and run through the crossbar towards the end
that abuts to the pump side arm. There the fish
lead exits the cross bar. Attach the winch cable
leads to the fish.
23