Low Level Device
Configuration
This section discusses:
•
•
Setting a VNM 250 Device as the System Controller
•
Configuring a VNM 250 Series Unit for DHCP
•
•
•
•
Initial Configuration
The RS-232 control port is used to configure the network settings for the VNE 250 and the
VND 250. Follow these instructions:
1.
Use an RS-232 cable to connect a control PC to the
of the
VNM 250 device (see page 19).
2.
On the PC or laptop, open a terminal emulation program, such as Extron DataViewer,
with the following settings:
•
Baud rate: 115200
•
Data bits: 8
•
Parity: None
•
Stop bits: 1
•
Flow control: None
NOTE:
DataViewer can be downloaded, free of charge, from
.
3.
Enter the
User
name
and
Password
.
NOTES:
•
When DataViewer first opens, it may be necessary to press <
Enter
> for the
User
name
prompt to appear.
•
By default, the User name is
config
and the Password is also
config
.
VNM 250 • Low Level Device Configuration
25
25