5-3
MTPX Plus Twisted Pair Matrix Switchers • Matrix Software
4
.
Follow the on-screen instructions. By default, the Windows installation of
the Matrix Switchers Control Program creates a C:\Program Files\Extron\
Matrix_Switchers directory, and it places the following four icons into a group
folder named “Extron Electronics\Matrix Switchers”:
•
MATRIX S Control Program
•
MATRIX S Help
•
Uninstall MATRIX Switcher
•
Check for Matrix Updates
N
Besides the LAN port, the MTPX Plus switcher can support remote control
via either the rear panel Remote RS-232/RS-422 Remote port or the front panel
Configuration port.
Remote RS-232/RS-422 port —
The port can be configured for either the
RS-232 or RS-422 serial communication protocol and operate at the 9600,
19200, 38400, or 115200 baud rate. See “Selecting the rear panel Remote port
protocol and baud rate” in chapter 3, “Operation”, to configure the rear panel
port from the front panel.
Configuration port —
The port supports RS-232 serial communication
protocol only. The port can operate at the 9600, 19200, 38400, or 115200 baud
rate, but Extron recommends leaving this port at the 9600 baud rate. See the
SIS commands on page 4-26 to configure either
port using an SIS command.
Software operation via Ethernet
When an MTPX Plus switcher is connected to an Ethernet WAN or LAN, up to
200 users can operate it, locally or remotely, using the Matrix Switchers Control
Program. See “Ethernet connection” in chapter 2, “Installation”, for installation
details.
Connection to the switcher via the Ethernet is password protected. There are two
levels of password protection: administrator and user. Administrators have full
access to all MTPX Plus switching capabilities and editing functions. Users can
select inputs and outputs, set and recall presets, and view all settings with the
exception of passwords. If the same password or no password is required for
logging on, all personnel log on with administrator privileges. Fields and functions
that exceed user privileges are grayed out in the Matrix Switchers Control Program
when the operator is logged on as a user.
Ethernet protocol settings
The IP Settings/Options screen (figure 5-7 on page 5-7) provides a location for
viewing and, if connected via the RS-232 link or if logged on via the LAN port as an
administrator, editing settings unique to the Ethernet interface. See “IP Settings/
Summary of Contents for MTPX Plus Series
Page 1: ...MTPX Plus Series Mini Twisted Pair Matrix Switcher 68 1383 01 Rev B 09 08 ...
Page 4: ......
Page 20: ...Introduction cont d MTPX Plus Twisted Pair Matrix Switchers Introduction 1 10 ...
Page 32: ...Installation cont d MTPX Plus Twisted Pair Matrix Switchers Installation 2 12 ...
Page 92: ...Operation cont d MTPX Plus Twisted Pair Matrix Switchers Operation 3 60 ...
Page 94: ...Operation cont d MTPX Plus Twisted Pair Matrix Switchers Operation 3 62 ...
Page 178: ...Ethernet Connection cont d MTPX Plus Twisted Pair Matrix Switchers Ethernet Connection A 8 ...