4-11
MTPX Plus Twisted Pair Matrix Switchers • Programmer’s Guide
Command/response table for SIS commands (continued)
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Audio/RS-232 TP input (wire pair 3 and 6) configuration
N
The RS-232 output insert ports, when enabled (
EX%
*
1Lrpt
}
), override the audio/RS-232 TP input configurations.
Configure input as audio
X#
*0\
Typ
X#
*0
]
Define the audio/RS-232
input as audio, such as
provided by an MTP 15HD A
transmitter.
Configure input as RS-232
X#
*1\
Typ
X#
*1
]
Define the audio/
RS-232 input as serial
communications, such
as provided by an
MTP 15HD RS transmitter.
Read TP input
configuration
X#
\
X$]
Show the audio/RS-232 wire
pair input definition.
RS-232 output inserts enables
Disable an RS-232 output
insert port
EX%
*0Lrpt
}
Lrpt
X%
*0
]
Disable the RS-232 insert on
the
X%
output.
Enable an RS-232 output
insert port
EX%
*1Lrpt
}
Lrpt
X%
*1
]
Enable the RS-232 insert on
the
X%
output.
Read RS-232 output insert
status
EX%
Lrpt
}
X^]
Show the status of the RS-232
output insert.
Input signal level/peaking and auto calibrate
Set input signal level
EX#
*
X&
Ipek
}
Ipek
X#
*
X&]
Set a specific pre-peak level
for the TP input.
Increment input peaking
EX#
+Ipek
}
Ipek
X#
*
X&]
Increase the input pre-
peaking level by 1.
Decrement input peaking
EX#
-Ipek
}
Ipek
X#
*
X&]
Decrease the pre-peaking
level by 1.
Read input peaking setting
EX#
Ipek
}
X&]
Execute auto calibration
EX#
*0AADJ
}
Aadj
X#
*2
]
{start}
Qik
]
{tie creation}
Aadj
X#
*
X*]
{finished}
Ipek
X#
*
X&]
{new value}
Tie input
X#
to output 1 and
auto adjust the peaking on
input
X#
. The
X*
value in
the response reports whether
the adjustment value was
within or outside of the
threshold.
N
Before issuing the auto calibration command:
1
. Disconnect the power and RJ-45 cables at the MTP transmitter connected to
X#
.
2
. Connect the two cables to the included MTP signal generator.
3
. If the input cable is longer than 300' (90 m), place the MTP signal generator’s
Pre-Peak switch on (up when the signal generator‘s RJ-45 connector is to the right
as shown at right). If the cable is shorter than 300’ (90 m), place the switch down.
Pre-Peak
is on
N
X#
= Input number
01 – (maximum number of inputs for your model)
X$
= Audio/RS-232 wire pair input type
0 = audio
1 = RS-232
X%
= RS-232 output insert port
MTPX Plus 168, 816, 1616
01 – 08
MTPX Plus 1632, 3216, 3232
01 – 16
X^
= RS-232 output insert status
0 = disabled
1 = enabled
X&
= Input signal level/peaking range
000 – 255
X*
= Threshold
0 = outside of threshold
1 = within threshold
Summary of Contents for MTPX Plus Series
Page 1: ...MTPX Plus Series Mini Twisted Pair Matrix Switcher 68 1383 01 Rev B 09 08 ...
Page 4: ......
Page 20: ...Introduction cont d MTPX Plus Twisted Pair Matrix Switchers Introduction 1 10 ...
Page 32: ...Installation cont d MTPX Plus Twisted Pair Matrix Switchers Installation 2 12 ...
Page 92: ...Operation cont d MTPX Plus Twisted Pair Matrix Switchers Operation 3 60 ...
Page 94: ...Operation cont d MTPX Plus Twisted Pair Matrix Switchers Operation 3 62 ...
Page 178: ...Ethernet Connection cont d MTPX Plus Twisted Pair Matrix Switchers Ethernet Connection A 8 ...