Programmer’s Guide, cont’d
MTPX Plus Twisted Pair Matrix Switchers • Programmer’s Guide
4-16
Command/response table for SIS commands (continued)
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional
description
Names (continued)
Write input name
EX#
,
X2!
NI
}
Nmi
X#
,
X2!]
Example:
E
1
,
Podium camNI
}
Nmi01
,
Podium cam
]
Name input 1
“Podium cam”.
Read input name
EX#
NI
}
X2!]
Write output name
EX#
,
X2!
NO
}
Nmo
X#
,
X2!]
Example:
E
1,Main PJ1NO
}
Nmo01,Main PJ1
]
Name output 1 “Main PJ1”.
Read output name
EX#
NO
}
X2!]
I/O Grouping
N
The group that is assigned in each of the following I/O grouping commands (
X2#
) must be 1, 2, 3, 4, or 0 (not grouped).
Write input grouping
EX2#
1
X2#
2
...
X2#
n
I
}
Gri
X2#
1
X2#
2
X2#
3
...
X2#
n
]
n
= the maximum number
of inputs. Each
X2#
entry
is the group number
assigned to an input
position, starting from input 1.
Example:
MTPX Plus 168
E
4013300004440443I
}
See below.
01
Input:
GrI
Response #s = group:
Input 1 in group 4
02 03 04 05 06 07 08 09 10 11 12
4 0 1 3 3 0 0 0 0 4 4 4
13 14 15 16
0 4 4 3
Input 2 not grouped Input 12 in group 4
Input 1 - Group 4, Input 2 -
Group 0 (not grouped), ...
Input 16 - Group 3.
N
You must enter and
X2#
value for each input in your matrix size, such as 32 inputs for an MTPX Plus 3216.
Write output grouping
EX2#
1
X2#
2
...
X2#
n
O
}
Gro
X2#
1
X2#
2
X2#
3
...
X2#
n
]
n
= the maximum
number of outputs. Each
X2#
entry is the group
number assigned to an output
position, starting from output 2.
Read input grouping
E
I
}
X2#
1
X2#
2
X2#
3
...
X2#
n
]
n
= the maximum number of
inputs. Each
X2#
entry is the
group number assigned to
an output position, starting
from input 1.
Example:
MTPX Plus 1616
E
I
}
See below.
01
Input:
Response = group:
Input 1 in group 1
02 03 04 05 06 07 08 09 10 11 12
1 1 1 3 3 0 0
0
0
4 4 4
13 14 15 16
0 4 4 4
Input 8 not grouped Input 12 in group 4
Read output grouping
E
O
}
X2#
1
X2#
2
X2#
3
...
X2#
n
]
n
= the maximum number of
outputs.
Save, recall, and directly write presets
N
• If you try to recall a preset that is not saved, the matrix switcher responds with the error code
E11
.
•
The following characters are invalid in preset names:
+ - , ` @ = [ ] { } ‘ “ ; : | \ and ?.
Save current configuration
as a global preset
X2)
,
Spr
X2)]
Command character is a
comma.
Example:
9
,
Spr9
]
Save current ties as preset 9.
Recall a global preset
X2)
.
Rpr
X2)]
Command character is a
period.
Example:
5
.
Rpr05
]
Recall preset 5, which
becomes the current
configuration.
N
X#
= Input number
01 – (maximum number of inputs for your model)
X2!
= Name
12 characters maximum for input and output names
X2#
= Group #
1 through 4 groups (0 = no group
X2)
= Global or room preset #
0 - 32, 10 maximum for a room preset (0 = current configuration)
Summary of Contents for MTPX Plus Series
Page 1: ...MTPX Plus Series Mini Twisted Pair Matrix Switcher 68 1383 01 Rev B 09 08 ...
Page 4: ......
Page 20: ...Introduction cont d MTPX Plus Twisted Pair Matrix Switchers Introduction 1 10 ...
Page 32: ...Installation cont d MTPX Plus Twisted Pair Matrix Switchers Installation 2 12 ...
Page 92: ...Operation cont d MTPX Plus Twisted Pair Matrix Switchers Operation 3 60 ...
Page 94: ...Operation cont d MTPX Plus Twisted Pair Matrix Switchers Operation 3 62 ...
Page 178: ...Ethernet Connection cont d MTPX Plus Twisted Pair Matrix Switchers Ethernet Connection A 8 ...