DSC HD-HD 4K Plus A Series Web Page
The embedded
DSC
HD-HD
4K
Plus
A
or
DSC
HD-HD
4K
Plus
A
xi
Web page enables you
to monitor and adjust certain settings of the DSC through its Ethernet port, connected
via a LAN or WAN and using a Web browser such as Microsoft
®
Internet Explorer
®
. This
factory-installed Web page is always available and cannot be erased or overwritten.
Accessing the Web Page
To access the HTML page:
1.
In the
Address
field of your Web browser, enter the IP address of your unit. To obtain
this address, do either of the following:
•
Press the front panel
Menu
button and select the
Communications
submenu. The
current IP address is the fourth item in the right panel.
•
SIS command:
E
CI
}
on page 66. See
, beginning on page 42, for information on entering these
commands.
NOTE:
If the local system administrators have not changed the IP address, use
the factory-specified default
192.168.254.254
in this field.
2.
Press the <Enter> key. The DSC checks to see if the Web page is password
protected.
•
If the unit is not password protected, the Web page opens.
•
If the unit is password protected, the
Authentication
Required
dialog box
opens (see figure 38).
Figure 38.
Example of a Network Password Dialog Box
3.
If an administrator or user password is required, enter
admin
or
user
in the
User
Name
field and the password in the
Password
field. Click
Log
In
.
DSC HD-HD 4K Plus A Series • Remote Configuration and Control
76