Volume
Each output channel volume block provides a mono long-throw
fader with a range of 0 to 100 dB of attenuation, and a volume
setting readout (in dB) below the fader. Volume level is adjustable
with the slider or by entering directly into the display window in
0.1 dB increments. Using the arrow buttons on the keyboard
provides 1 dB increments.
An individual
Mute
button provides control of channel muting.
Output polarity switching is also provided with a button that toggles
between plus and minus polarity.
The default setting is unmuted, at 0 dB attenuation. A peak meter
displays the real-time audio level from -60 to 0 dBFS.
The
OK
button accepts settings and closes the dialog with a single
click, while the
Cancel
button ignores changes and closes the
dialog.
DMP 64 • Operation
48
Summary of Contents for DMP 64
Page 4: ......