40
Chapter11
TABLE OF DISPLAY MESSAGES
ALARMS
Message
Cause
Solution
Display D1
Indicates the presence of an alarm
This indicator lights up when one of the alarms described
below is in progress and is accompanied by the
corresponding indication on display D1. To reset the alarm,
press button 1 and hold for three seconds when the stove is
completely cold.
If the light is fl ashing, it indicates that the depression sensor
is deactivated.
All resetting operations must be carried out by an
authorised technician
.
GAS FAN
The fl ue gas motor is blocked
The speed control probe is faulty.
No power supply to the fl ue gas motor.
All resetting operations must be carried out by an
authorised technician
GAS PROBE
The exhaust fl ue gas probe is broken.
The exhaust fl
ue gas probe is
disconnected from the board.
All resetting operations must be carried out by an
authorised technician
HIGH GAS TEMP
The cross-fl ow fan is faulty.
Excessive pellet feed.
No power supply to the cross-fl ow fan.
Adjust the fl ow of pellets (see “Pellet Load Adjustment”).
Other resetting operations must be carried out by an
authorised technician.
DEPRESSION
The fl ue gas exhaust pipe is obstructed.
The air inlet is blocked.
The combustion chamber is dirty.
The pressure sensor is faulty.
The ash drawer is not closed properly.
The door is not closed properly.
Check to make sure that the exhaust outlet and the
combustion chamber are clean.
Check that the air inlet is not blocked.
Check to see if the drawer is sealed properly.
Check to see if the door is sealed properly.
Other resetting operations must be carried out by an
authorised technician.
NO FLAME
The pellet tank is empty.
The spark plug is faulty or out of
position.
Inadequate pellet load setting.
Check the level in the pellet tank.
Check the procedures described in “Ignition”.
Other resetting operations must be carried out by an
authorised technician.
NO FLAME
BLACK OUT
No electricity during the lighting phase.
Press button 1 to switch
OFF
the stove and repeat the
procedure described in “Ignition”.
Other resetting operations must be carried out by an
authorised technician.
NO PELLET
The pellet tank is empty.
Pellet feeding is insuffi
cient.
The feed motor still has to settle in.
The geared motor is not loading pellets.
Check the level in the pellet tank.
Adjust the fl ow of pellets (see “Pellet Load Adjustment”).
Other resetting operations must be carried out by an
authorised technician.
CLEANING WAIT
+
alarm
Attempt to release alarm with stove still
cooling
Every time the stove visualises one of the above-listed
alarms it will automatically switch off .
The stove will block any attempt to release the alarm during
this phase visualising the alarm itself and
CLEANING WAIT
alternately .
Release of the alarm using button 1 is only possible when
the appliance is switched off .
TEL
- - - - - - - - - -
Display of the service centre telephone
number.
When an alarm occurs, the type of alarm detected and the
telephone number of the service centre fl ash on the display
in alternation.
If the number has not been entered, the display shows a
series of dashes.