20
4.2.1 M-SET: MODUS
Allows you to set the device into test-, armed- or sleep-mode.
4.2.2 M-SET: BOX
Allows you to set the main box of the device from 1-99.
4.2.3 M-SET: SEC-KEY
Allows you to set the Secure-Key of the device (Standard 139). The Secure-Key can be used to
encrypt the radio transmission within a systemaddress seperately. Transmitters can only control
devices set to the same Secure-Key.
4.2.4 M-SET: FREQUENCY
Allows you to change the frequency of the internal radio module (Standard 6, minimum 1, maximum
10).
4.2.5 M-SET: POW ER
Allows you to change the radio modules power output (Standard 10).
4.2.6 M-SET: TIMEOUT
Allows you to set the time, after how many seconds the receiver will the stop the internal
synchronization after the transmitter has stopped sending signals (In seconds from 6 to 99seconds, or
"infinity", standard 30sec). The longest option of "infinity" is available, meaning that the Wave Flamer
will continue the show until the end, regardless of radio troubles.
A show in infinity-mode can be stopped anytime by a manual
signal. However we still recommend using this mode only if
there are no expected dangers from the device during any
point of the show.
4.2.7 M-SET: LOCK
Allows you to lock the receiver menu. Also allows you to set the code needed to unlock the menu.
4.2.8 M-SET: SYS
Allows you to change the systemaddress of the receiver.
4.2.9 M-SET: POS 1-15 (IGNTIME)
Allows you to set the opening- or ignition time of short single ignitions (Position 1-15, standard 40ms).